User`s manual

24
Changing RY19 Multi-Function I/O Allocation
The drives multi-function I/O layout will change as shown below when RY19 is switched on or off.
Parameter Name RY19: OFF (Default) RY19: ON
H1-01 Multi-function input 1 24: External fault 3: Multi-step speed reference 1
H1-02 Multi-function input 2 14: Fault reset 4: Multi-step speed reference 2
H1-03 Multi-function input 3 3: Multi-step speed reference 1 5: Multi-step speed reference 3
H1-04 Multi-function input 4 4: Multi-step speed reference 2 6: Jog command
H1-05 Multi-function input 5 6: Jog command 1A: Accel/decel time selection 2
H1-06 Multi-function input 6 8: Baseblock command 8: Baseblock command
H2-01 Multi-function output 1 0: Running 0: Running
H2-02 Multi-function output 2 1: Zero speed 5: Frequency detection 2
H2-03 Multi-function output 3 2: Frequency agreement E: Fault
H3-05 Multi-func analog input 0: Auxiliary frequency reference 1F: Analog input is not used.
L4-01 Freq detection level 0.00Hz 6.00Hz
Remote Registers
(From PLC to Inverter)
Remote Register Name Description
RW
W0
Monitor code
Sets the monitor code. While the monitor execution request flag (RYC)
is ON after setting the code, the monitored value is stored in RW
RO
.
While RW
RO
is being updated, the monitoring signal (RXC) is turned
ON.
RW
W1
Setting
frequency
Sets the operation frequency. If the RYD flag is turned ON now, this
data sent to the inverter is assigned as the master speed frequency.
Turning ON the RYE flag writes in the setting to frequency reference 1
and stores the data in EEPROM
*
. However, the unit of the setting
depends on the setting of o1-03 (frequency reference setting/display
unit selection).
RW
W2
Command code
Sets the command code to execute parameter read/write, fault history,
or error reset, etc. If the command code execution request flag (RYF)
is turned ON, the inverter processes the corresponding command code,
and the command code execution completion flag (RXF) is turned ON
after the command is carried out.
RW
W3
Write data
Assigns the data when necessary for the command code.
Turn ON the command code execution request flag (RYF) after setting
the command code and write-in data.
* The EEPROM can be written to 100,000 times. Refrain from writing to EEPROM excessively.