Instruction manual

6. Programming Features
139
* 1. When reading is enabled (n177=1), this setting is not necessary.
* 2. This setting is not necessary unless read-prohibition is selected.
COPY Function
This function writes the constants stored inside the Digital Operator in
batch to the Inverter. Write-in is possible only for Inverters with the
same product series, power supply specifications, and control mode (V/
f control or vector control).
Therefore, writing from 200 V Class to 400 V Class Inverters (or vice
versa), from V/f control mode to vector control mode Inverters (or vice
versa), or from VS-606V7 to VS mini J7 Inverters is not possible.
The Constant Copy Function Selection (n176), Constant Read Selection
Prohibit (n177), Fault History (n178), Software Version No. (n179), and
hold output frequency are not written. vAE will appear (flashing) if the
capacities of the Inverters differ.
Press to continue writing (the COPY function).
• Execute read-out
(READ) using the
Constant Copy
Function Selec-
tion (n176).
Change the constant No.
by pressing the or
key.
• Press to dis-
play the set value.
Change the set value to
rEd by pressing the or
key.
• Press .
• Press or
.
(Lit)
(Lit)
(Flashes while executing the read)
(End is displayed after the
read has been completed.)
(The constant No. is displayed.)
• Set Constant
Read Prohibited
Selection (n177)
to read-dis-
abled.
*2
Change the constant No.
to n177 by pressing the
or key.
• Press to dis-
play the set value.
Change the set value to
0 by pressing the or
key.
• Press .
(Lit)
(Flashes)
(Lit for one second.)
(The constant No. is displayed.)
Explanation Operator Display
ENTER
ENTER
DSPL
ENTER
ENTER
ENTER
ENTER