Instruction manual

6. Programming Features
143
While a constant No. that is not the same is displayed or a constant
value is displayed, press to interrupt the execution of the
verification. End will be displayed. Press or to return
to the constant No. display.
Inverter Capacity Display
The voltage class and maximum applicable motor capacity for which
constants are stored in the Digital Operator are displayed.
Example: Displaying Voltage Class and Maximum Applicable Motor
Capacity for Inverter whose Constants are in EEPROM in
Operator
• Execute VERIFY
by Constant
Copy Function
Selection (n176).
Change the constant No.
to n176 by pressing the
or key.
• Press to display
the set value.
(Lit)
Change the set value to
vFy by pressing the or
key.
(Lit)
• Press .
(Flashes while executing the verifi-
cation)
• Display the
unmatched
constant No.
(Flashes)
(When n011 is different.)
• Display the
constant value in
the Inverter.
• Press .
(Flashes)
Display the con-
stant value in the
Digital Operator.
• Press .
(Flashes)
• Continue the
execution of
VERIFY.
Press the key.
(Flashes while executing
the verification)
(End is displayed when the
verification has been completed.)
• Press or
.
(The constant No. is dis-
played.)
Explanation Operator Display
ENTER
ENTER
ENTER
ENTER
DSPL
ENTER
STOP/RESET
DSPL
ENTER