Instruction manual

9. Specifications
207
* 1. Values are doubled for 400 V Class.
* 2. 10.0 V for 5.5 kW and 7.5 kW Inverters of 200-V Class and 20.0 V of
400-V Class.
Factory Settings That Change with the Inverter Capacity
200 V Class 3-phase
* Sets the value of the motor resistance for one phase.
No. Name V/f Control
Mode
(n002 = 0)
Vector Con-
trol Mode
(n002 = 1)
n014 Mid. Output Frequency 1.5 Hz 3.0 Hz
n015 Mid. Output Frequency Voltage
12.0 V
*1
*2
11.0 V
*1
n016 Min. Output Frequency 1.5 Hz 1.0 Hz
n017 Min. Output Frequency Voltage
12.0 V
*1
*2
4.3 V
*1
n104 Torque Compensation Time Constant 0.3 s 0.2 s
n111 Slip Compensation Gain 0.0 1.0
n112 Slip Compensation Gain Time Constant 2.0 s 0.2 s
No. Name Unit Factory Setting
- Inverter Capacity kW
0.1
kW
0.2
kW
0.4
kW
0.75
kW
1.5
kW
2.2
kW
3.7
kW
5.5
kW
7.5
kW
n036 Motor Rated Current A 0.6 1.1 1.9 3.3 6.2 8.5 14.1 19.6 26.6
n105 Torque Compensation
Iron Loss
W 1.7 3.4 4.2 6.5 11.1 11.8 19 28.8 43.9
n106 Motor Rated Slip Hz 2.5 2.6 2.9 2.5 2.6 2.9 3.3 1.5 1.3
n107 Motor Line-to-neutral
Resistance*
17.99 10.28 4.573 2.575 1.233 0.8 0.385 0.199 0.111
n108 Motor Leakage
Inductance
mH 110.4 56.08 42.21 19.07 13.4 9.81 6.34 4.22 2.65
n110 Motor No-load
Current
%727362554535322630