Instruction manual

208
• 200 V Class Single-phase
* Sets the value of the motor resistance for one phase.
• 400 V Class 3-phase
* Sets the value of the motor resistance for one phase.
No. Name Unit Factory Setting
- Inverter Capacity kW
0.1 kW 0.2 kW 0.4 kW 0.75 kW 1.5 kW 2.2 kW 3.7 kW
n036 Motor Rated Current A 0.6 1.1 1.9 3.3 6.2 8.5 14.1
n105 Torque Compensation
Iron Loss
W 1.7 3.4 4.2 6.5 11.1 11.8 19
n106 Motor Rated Slip Hz 2.5 2.6 2.9 2.5 2.6 2.9 3.3
n107 Motor Line-to-neutral
Resistance*
17.99 10.28 4.573 2.575 1.233 0.8 0.385
n108 Motor Leakage
Inductance
mH 110.4 56.08 42.21 19.07 13.4 9.81 6.34
n110 Motor No-load Current % 72 73 62 55 45 35 32
No. Name Unit Factory Setting
- Inverter Capacity kW
0.2 kW 0.4 kW 0.75
kW
1.5
kW
2.2
kW
3.0
kW
3.7
kW
5.5
kW
7.5
kW
n036 Motor Rated Current A 0.6 1.0 1.6 3.1 4.2 7.0 7.0 9.8 13.3
n105 Torque Compensation Iron
Loss
W 3.4 4.0 6.1 11.0 11.7 19.3 19.3 28.8 43.9
n106 Motor Rated Slip Hz 2.5 2.7 2.6 2.5 3.0 3.2 3.2 1.5 1.3
n107 Motor Line-to-neutral
Resistance*
41.97 19.08 11.22
5.044 3.244 1.514 1.514 0.797 0.443
n108 Motor Leakage Inductance mH 224.3 168.8 80.76
53.25 40.03 24.84 24.84 16.87 10.59
n110Motor No-load Current % 73 63 52 453533332630