Instruction manual

3. Mounting
27
• The same space is required horizontally and vertically and
right and left for both Open Chassis (IP00, IP20) and
Enclosed Wall-mounted (NEMA 1) Inverters.
• Always remove the top and bottom covers before install-
ing a 200 or 400 V Class Inverter with an output of 5.5/7.5
kW in a panel.
Mounting/Removing Components
Removing and Mounting the Digital Operator and Covers
Removing the Front Cover
Use a screwdriver to loosen the screw
on the front cover and then remove it
in direction 1. Then press the right
and left sides in direction 2 and lift the
front cover in direction 3.
Mounting the Front Cover
Mount the front cover by reversing
the order of the above procedure for
removal.
Removing the Terminal Cover
• Inverters with Width of 108 mm,
140 mm or 170 mm
After removing the front cover,
press the right and left sides of the
terminal cover in direction 1 and
lift the terminal cover in direction
2.
NOTE