Description of Status Indicators
There are two Inverter operation status indicators on the middle right
section of the face of the VS-606V7. The combinations of these indica-
tors indicate the status of the Inverter (ON, flashing, and OFF). RUN
indicator and status indicator on the button have the same func-
tion.
For details on how the status indicators function for Inverter faults, refer
to Chapter 8. Fault Diagnosis. If a fault occurs, the ALARM indicator
will lit.
The fault can be reset by turning ON the FAULT RESET sig-
nal (or by pressing the key on the Digital Operator)
with the operation signal OFF, or by turning OFF the power
supply. If the operation signal is ON, the fault cannot be reset
using the FAULT RESET signal.
:ON
:Flashing (long flashing) :Flashing :OFF
RUN
ALARM
(Green)
(Red)
Operation ready
(During stop)
Ramp to
stop
Normal
operation