Instruction manual

6. Programming Features
79
n065 Setting
Pulse train signal can be selected by setting in n150.
At the factory setting, the pulse of 1440 Hz can be output when output
frequency is 100 %.
n065 Setting Description
0 Analog monitor output
1 Pulse monitor output
(Output frequency monitor)
n150 Setting Description
0 Output
frequency
monitor
1440 Hz/Max. frequency (n011)
1 1F: Output frequency × 1
6 6F: Output frequency × 6
12 12F: Output frequency × 12
24 24F: Output frequency × 24
36 36F: Output frequency × 36
40 Frequency
reference
monitor
1440 Hz/Max. frequency (n011)
41 1F: Output frequency × 1
42 6F: Output frequency × 6
43 12F: Output frequency × 12
44 24F: Output frequency × 24
45 36F: Output frequency × 36
Pulse Monitor Output
Pulse
Output Frequency
1440 Hz
100 %
AM
AC (0 V)