Instruction manual

6. Programming Features
89
* 1. For more information on how to select the sequence polarity, refer to page
188.
* 2. Numbers 1 to 7 are displayed for to indicate the terminal numbers S1 to
S7.
16 ACCELERATION/
DECELERATION HOLD
command
76
17 LOCAL/REMOTE selection 62
18 Communications/control cir-
cuit terminal selection
92
19 Emergency stop fault,
NO contact input
Inverter stops for an emergen-
cy stop signal input according
to the Stopping Method Selec-
tion (n005). When frequency
coasting to a stop (n005 is set
to 0) is selected, the Inverter
coasts to a stop according to
Deceleration Time Setting 2
(n022).
Digital Operator displays
.
-
20 Emergency stop alarm,
NO contact input
-
21 Emergency stop fault,
NC contact input
-
22 Emergency stop alarm,
NC contact input
-
23 PID control cancel 134
24 PID integral reset 134
25 PID integral hold 134
26 Inverter overheat alert
(OH3 alarm)
When the Inverter overheat
signal turns ON, (flash-
ing) is displayed at the Digital
Operator.
-
27 Acceleration/deceleration
time selection 2
-
34 UP/DOWN commands Setting enabled only for n056
(terminal S7)
91
35 Self-test Setting enabled only for n056
(terminal S7)
122
36 UP/DOWN command 2 Setting enabled only for n056
(terminal S7)
-
Setting Name Description Ref.