User`s manual

150
List of Parameters Chapter 10
n39
(0127)
Multi-function
input 4 (Input
terminal S5)
2 Reverse/
Stop
Reverse rotation
command in 2-wire
sequence
(Reversed with the
terminal turned ON)
2 to 8,
10 to
22, 34,
35
16No 5-17
3 External
fault (NO)
ON: External fault
(FP_ detection: _ is a
terminal number)
4 External
fault (NC)
OFF: External fault
(EF_ detection: _ is a
terminal number)
5 Fault reset ON: Fault reset
(disabled while RUN
command is input)
6 Multi-step
speed
reference 1
Signals to select
freqency references 1
through 8.
Refer to 5-5-4 Setting
Frequency
References through
Key Sequences for
the relationship
between multi-step
speed references and
frequency references.
7 Multi-step
speed
reference 2
8 Multi-step
speed
reference 3
10 Inching
frequency
command
ON: Inching
frequency command
(taking precedence
over the multi-step
speed reference)
11 Accelera-
tion/Deceler-
lation time
changeover
ON: Acceleration time
2 and deceleration
time 2 are selected.
12 External
base block
command
(NO)
ON: Output shut off
(while motor coasting
to a stop and “bb”
flashing)
13 External
base block
bommand
(NC)
OFF: Output shut off
(with motor free
running and “bb”
flashing)
14 Search
command
(Searching
starts from
maximum
frequency)
ON: Speed search
(Searching starts from
n09)
15 Search
command
(Searching
starts from
preset
frequency)
ON: Speed search
16 Accelera-
tion/Deceler-
ation prohibit
command
ON: Acceleration/
Deceleration is on
hold (running at
parameter frequency)
17 Local or
remote
selection
ON: Local mode
(operated with the
Digital Operator)
Para-
meter No.
(Register
No. (Hex))
Name Description Setting
range
Unit of
setting
Default
setting
Changes
during
operation
Refer-
ence
page