User`s manual

151
List of Parameters Chapter 10
n39
(0127)
Multi-function
input 4 (input
terminal S5)
18 Communi-
cations or
remote
selection
ON: RS-422A/485
communications input
is enabled.
OFF: The settings of
n02 and n03 are
enabled.
2 to 8,
10 to
22, 34,
35
16No 5-17
19 Emergency
stop fault
(NO)
The Inverter stops
according to the
setting in n04 for
interruption mode
selection with the
emergency stop input
turned ON.
NO. Emergency stop
with the contact
closed.
NC: Emergency stop
with the contact
opened.
Fault: Fault output is
ON and reset with
RESET input. Alarm
output is ON (no reset
required).
“STP“ is displayed (lit
with fault input ON
and flashed with
alarm input ON)
20 Emergency
stop alarm
(NO)
21 Emergency
stop fault
(NC)
22 Emergency
stop alarm
(NC)
34 Up or down
command
Up or down command
(set in n39 only)
By setting n39 to 34,
the set value in n38 is
ignored and the
following setting are
forcibly mde.
S4: Up command
S5: Down command
35 Self-
diagnostic
test
ON: RS-422A/485
communications self-
diagnostic test (set in
n39 only)
Para-
meter No.
(Register
No. (Hex))
Name Description Setting
range
Unit of
setting
Default
setting
Changes
during
operation
Refer-
ence
page