Operation Example Chapter 4-2
4-2 Operation Example
4-2-1 Power Connection
Checkpoints before Connecting the Power Supply
Check that the power supply is on the correct voltage and that the motor
output terminals (R/L1, S/L2, and T/L3) are connected to the motor
correctly.
CIMR-J7AZ-2_: Three-phase 200 to 230 V AC
CIMR-J7AZ-B_: Single-phase 200 to 240 V AC (Wire R/L1 and S/L2)
CIMR-J7AZ-4_: 3-phase 380 to 460 V AC
Make sure that the motor output terminals (U/T1, V/T2, and W/T3) are
connected to the motor correctly.
Ensure that the control circuit terminals and the control device are wired
correctly. Make sure that all control terminals are turned off.
Set the motor to no-load status (i.e., not connected to the mechanical
system).
Connecting the Power Supply
After conducting the above checks, connect the power supply.
4-2-2 Check the Display Status
If the display is normal when the power is connected, it will read as
follows:
Normal
RUN indicator: Flashes
ALARM indicator: Off
Setting/Monitor indicators: FREF, FOUT, or IOUT is lit.
Data display: Displays the corresponding data for the indicator that is lit.
When a fault has occurred, the details of the fault will be displayed. In that
case, refer to Chapter 8 Maintenance Operations and take necessary
action.
Fault
RUN indicator: Flashes
ALARM indicator: Lit (fault detection) or flashes (alarm detection)
Setting/Monitor indicators: FREF, FOUT, or IOUT is lit.
Data display: The fault code, such as UV1, is displayed. The display will
differ depending on the type of fault.