User`s manual

65
Multi-function I/0 Chapter 5-9
Operation in 2-wire Sequence (Set Value: 2)
The Inverter operates in 2-wire sequence by setting a multi-function input
parameter to 2 (reverse/stop).
The following diagram shows a wiring example of the terminals in 2-wire
sequence.
Operation in 3-wire Sequence (n37 = 0)
The Inverter operates in 3-wire sequence by setting n37 for multi-function
input 2 to 0.
• Only n37 can be set to 0 (3-wire sequence). By making this setting, the
set value in n36 is ignored and the following settings are forcibly made.
S1: RUN input (RUN when ON)
S2: STOP input (STOP when OFF)
S3: Forward/Reverse rotation command (OFF: Forward; ON: Reverse)
The following diagram shows a wiring example of the terminals in 3-wire
sequence.
External Base Block Command (Set Value: 11, 12)
When an SPST-NO (setting: 12) or SPST-NC (setting: 13) input is received,
Inverter outputs are shut OFF. Use these inputs in the following cases to stop
Inverter outputs.
For switching the motor to free running status when applying an external
brake.
For stopping Inverter outputs before disconnecting motor wiring when
changing the motor connections from the Inverter to a commercial power
supply.
Note The external base block only shuts OFF the Inverter’s output frequency, and
the Inverter’s internal frequency continues to be calculated as usual.
Therefore, if the external base block is clearedwhen the frequency is other
than zero, the frequency calculated at that point will be output. Because of
this, if the baseblock is cleared during deceleration while the motor is free
running, a large discrepancy between the motor speed at that moment and
the Inverter output frequency may result in a main circuit overvoltage (OV) or
overcurrent (OC).
Forward-rotation
switch
Reverse-rotation
switch
Forward/Stop (Forward rotation with the forward-rotation switch
closed and reverse-rotation switch opened)
Reverse/Stop (Reverse rotation with the reverse-rotation switch
closed and forward-rotation switch opened) _: 2 to 5
Sequence input common
S1
S_
SC
Stop switch
(NC)
Operation
switch (NO)
Direction switch
RUN input (RUN with the STOP switch and RUN switch closed)
STOP input (with the STOP switch opened)
Foward/Reverse rotation command (Forward rotation with the direction
switch opened and reverse rotation with the direction switch closed
Sequence input common
S1
S2
S3
SC