User`s manual

85
Other Functions Chapter 6-7
6-7-7 UP/DOWN Command Frequency Memory (n62)
This function changes the reference frequency by turning the UP and
DOWN commands on and off.
In order to use this function, set n39 for multi-function inputs 4 to 34. Then
the multi-function input 3 (S4) and multi-function input 4 (S5) terminals
are set as described below.
Multi-function input 3 (S4): UP command (The value in n38 for multi-
function input 3 is ignored.)
Multi-function input 4 (S5): DOWN command
The output frequency held by the UP/DOWN function will be stored in the
memory if n62 for UP/DOWN command frequency memory is set to 1.
By setting n62 to 1, the frequency reference kept on hold for 5 s or more
will be retained even after a power interruption, and operation will be
restarted at this frequency the next time the RUN command is input.
The stored output frequency will be cleared from the memory if n62 is set
to 0. The retained frequency is initialized with n01 for parameter
initialization set to 8 or 9.
Note While this function is used, frequency references can be used with the UP/
DOWN command or inching frequency command. All multi-step speed
references are disabled.
n62 Frequency Hold Function Selector Changes during
operation
No
Setting
range
0, 1 Unit of
setting
1 Default setting 0