Configure the power indicator LED.
Navigate to:
http://<phoneIPAddress>/servlet?p=featur
es-powerled&q=load
Details of Configuration Parameters:
Parameters
Permitted
Values
Default
phone_setting.common_power_led_enable
0 or 1
0
Description:
Enables or disables the power indicator LED to be turned on.
0-Disabled (power indicator LED is off)
1-Enabled (power indicator LED is solid red)
Web User Interface:
Features->LED->Common Power Light On
Phone User Interface:
None
phone_setting.ring_power_led_flash_enable
0 or 1
1
Description:
Enables or disables the power indicator LED to flash when the Skype for Business phone
receives an incoming call.
0-Disabled (power indicator LED does not flash)
1-Enabled (power indicator LED fast flashes (300ms) red)
Web User Interface:
Features->LED->Ring Power Light Flash
Phone User Interface:
None
phone_setting.mail_power_led_flash_enable
0 or 1
0
Description:
Enables or disables the power indicator LED to flash when the Skype for Business phone
receives a voice mail.
0-Disabled (power indicator LED does not flash)
1-Enabled (power indicator LED slow flashes (1000ms) red)
Web User Interface: