Specifications

153
Manufacturer reserves the rights to change specications without prior notice.
Technical features
INDOOR UNITS
Cooling only and Reverse cycle SICH 70 76 90 120 150 180 240 300
CONDENSING UNITS
Cooling only models SCOC --- 76 90 --- 150 180 --- ---
Cooling capacity kW 21,00 29,00 40,00 54,00
Power input in cooling kW 9,01 13,20 19,10 27,00
Refrigerant charge on site
for 7m piping length
Kg 8,7 13,8 9,4 x 2 9 x 2
Reverse cycle models SCOH 70 76 90 120 150 180 240 300
Cooling capacities kW 18,60 21,00 30,00 33,30 39,50 54,00 69,00 86,00
Power input in cooling kW 6,40 8,80 11,70 13,90 18,90 26,40 31,30 35,00
Heating capacities kW 18,60 22,30 33,50 34,40 44,00 56,00 69,00 88,00
Power input in heating kW 6,00 5,50 12,80 12,10 15,80 26,40 31,30 32,60
Refrigerant charge on site
for 7m piping length
Kg 8,4 8,7 13,8 13 9,4 x 2 9 x 2 13 x 2 16 x 2
In duct condensing side
sound power level SCOC / SCOH
dB(A) - / 71 79 / 74 79 / 77 - / 91 78 / 78 80 / 80 - / 80 - / 80
In duct indoor side sound power level dB(A) 81/ 70 81/ 70 81/ 77 84 85 86 86 86
Power supply 400V/3 + N/ 50Hz
Nominal / Starting current A 17 / 99 20 / 123 24 / 134 29 / 167 37 / 2 x 99 49 / 2 x 134 59 / 2 x 167 76 / 2 x 189
Main switch (1) A 20 25 32 40 50 63 80 100
Main cable to the condensing unit (1) Nbr x mm
2
5 x 4 5 x 4 5 x 6 5 x 10 5 x 10 5 x 16 5 x 25 5 x 35
Interconnecting cable (1) Nbr x mm
2
4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5 4 x 2,5
Cable to standard thermostat (1) (2) Nbr x mm
2
10 x 0,22
Insulated refrigerant piping
Suction 1 1/8” 1 1/8” 1 1/8” 1 1/8” 2 x 1 1/8” 2 x 1 1/8” 2 x 1 3/8” 2 x 1 3/8”
Liquid 1/2” 1/2” 5/8” 5/8” 2 x 1/2” 2 x 5/8” 2 x 7/8” 2 x 7/8”
Evaporator fan SICH
at nominal airow (3)
Airow m
3
/h 4 530 4 530 8 500 8 300 10 700 13 600 16 500 19 500
Standard ESP Pa 62 62 62 75 75 80 80 80
ESP With HSD Pa - - 138 150 - - - -
ESP With HSDM Pa 165 165 - - 112 164 156 187
Condenser fan
at nominal airow
Airow m
3
/h 6 300 6 300 11 520 11 520 12 600 18 000 23 400 23 400
Standard ESP Pa 50 50 50 50 50 50 50 50
Nett dimensions
condensing units
Height mm 1 392 1 392 1 526 1 526 1 592 1 641 1 794 1 794
Length mm 1 360 1 360 1 738 1 738 2 040 2 239 2 639 2 639
Depth mm 728 728 725 725 728 777 857 857
Nett dimensions
indoor
Height mm 590 590 663 663 663 762 838 838
Length mm 1 357 1 357 1 738 1 738 2 038 2 239 2 639 2 639
Depth mm 725 725 725 725 725 777 857 857
Nett weight
SCOC kg - 315 370 - 555 645 - -
SCOH kg 305 325 375 385 560 650 720 750
SICH kg 120 120 165 165 195 240 310 310
(1) For information only. These should be checked for compliance with local regulations depending also on installation and conductor type.
(2) Shield type cable will have a better insulation against electromagnetic interference. It is recommended for sensitive sites and for communications.
(3) ESP = External static pressure HSD = High speed drive HSDM = High speed drive and motor
All the data are at EUROVENT conditions with 230V/1/50Hz or 400V/3+N/50Hz.
Cooling : Entering indoor coil temp. 27°C / 19°C WB and outdoor temperature 3C
Heating : Entering indoor coil temp. 20°C and outdoor temperature C / 6°C WB
Large Split (Ductable)
E-COM-R0805