Specifications

135
Manufacturer reserves the rights to change specications without prior notice.
Roomtop
Compatibility table / Codes
Cooling only models
RTC 07 L RTC 10 L RTC 15 L RTC 20 L RTC 25 L RTC 30 L
661240701 661241003 661241503 661242003 661242503 661243003
Reverse cycle models
RTH 07 L RTH 10 L RTH 15 L RTH 20 L RTH 25 L RTH 30 L
662040701 662041003 662041503 662042003 662042503 662043003
Thermostat
Delivered as standard with the unit
DPC-1
Accessories
or options
Remarks Code
RTC 07 L RTC 10 L RTC 15 L RTC 20 L RTC 25 L RTC 30 L
RTH 07 L RTH 10 L RTH 15 L RTH 20 L RTH 25 L RTH 30 L
Electrical
Heaters *
(in duct)
5 kW / 1ph. 611765561
A
l
5 kW / 3ph. 611765573
l l
10 kW / 3ph. 611765533
l l
5 kW / 3ph. 611765653
l l l l
10 kW / 3ph. 611765583
l l l l
15 kW / 3ph. 611765513
l l l l
Low ambient regulation
613111533
O
l l l
613113087 *
l l l
Copper-copper coils unit
O
l l l l l l
Anti-corrosion blue n coil
O
l l l l l l
A=Accessory (supplied loose).
O=Option (factory tted).
O/A=If you want this item factorytted, precise it in the order form.
* Not protected against external conditions.
Technical features
Cooling only models RTC 07 L RTC 10 L RTC 15 L RTC 20 L RTC 25 L RTC 30 L
Cooling capacities
kW 7.60 9.90 14.60 19.90 22.20 27.00
Power input in cooling
kW 3.00 3.95 5.50 8.60 10.00 12.00
In duct outdoor side sound power level
dB(A) 71 71 72 74 77 81
In duct indoor side sound power level
dB(A) 70 71 71 73 75 75
Reverse cycle models RTH 07 L RTH 10 L RTH 15 L RTH 20 L RTH 25 L RTH 30 L
Cooling capacities
kW 7.40 9.30 14.10 19.90 22.20 26.80
Power input in cooling
kW 3.00 3.88 5.40 8.32 10.04 11.63
Heating capacities
kW 7.40 11.70 13.80 17.80 20.80 25.40
Power input in heating
kW 2.76 3.64 4.84 7.15 7.89 9.67
In duct outdoor side sound power level
dB(A) 71 72 74 74 81 81
In duct indoor side sound power level
dB(A) 70 72 73 73 81 81
Common characteristics
Power supply
230V/1/50Hz 400V/3 + N/ 50Hz
Nominal current RTC / RTH
A 14.3 / 16 9.5 / 9.7 11.6 / 11.5 19 / 19 21 / 21 23 / 23
Starting current
A 82 48 64 95 111 118
Main switch (1)
A 25 16 20 25 25 32
Main cable (1)
Nbr.xmm
2
3 x 4 5 x 2.5 5 x 4 5 x 4 5 x 4 5 x 6
Cable to standard thermostat (2)
Nbr.xmm
2
10 x 0.22
Evaporator fan
at nominal airow
Airow
m
3
/h 1 490 2 015 3 580 4 100 5 060 5 300
Standard ESP
Pa 25 37 50 50 62 62
Condenser fan
at nominal airow
Airow
m
3
/h 2 420 3 520 3 890 4 810 5 640 7 450
Standard ESP
Pa 50 50 50 50 50 50
Nett dimensions
Height
mm 480 557 557 585 650 650
Length
mm 1 102 1 155 1 312 1 575 1 750 1 770
Depth
mm 1 102 1 155 1 312 1 575 1 656 2 056
Nett weight RTC
kg 172 180 235 305 358 420*
Nett weight RTH
kg 178 190 243 317 379 434*
(1) For information only. These should be checked for compliance with local regulations depending also on installation and cable type
(2) Shield type cable only
All the data are at EUROVENT conditions with 230V/1/50Hz or 400V/3+N/50Hz.
Cooling : Entering indoor coil temp. 27°C / 19°C WB and outdoor temperature 3C
Heating : Entering indoor coil temp. 20°C and outdoor temperature C / 6°C WB
* Preliminary data
E-COM-R0801