User manual

7
ELECTRICAL CONNECTION
The oven is designed to be connected to 240V - 50Hz
electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
"L" Live Terminal
"N" Neutral Terminal
Earth
THIS APPLIANCE MUST BE EARTHED
The cable used to connect he oven to the electrical
supply should have the characteristics indicated in the
table.
If you require a direct connection to the electric network
(mains), it is necessary that you install an omnipole
switch between the appliance and the mains, with a
minimum gap of 3 mm between the switch contacts
and of a type suitable for the required lead in
compliance with the current rules.
This switch must be easily accessible to the user on
completion of the installation and must not break the
yellow and green earth cable at any point.
In order to connect the oven it is necessary to remove
the plate at the back of the oven to reach the terminal
block. Connect the brown insulated wire to the terminal
marked "L".
Connect the blue insulated wire to the terminal marked
"N".
Connect the green and yellow insulated wire to the
terminal marked .
Tighten the cable clamps ensuring that there is no
strain on the mains terminal.
Replace the cover and tighten securing screws.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a tempera-
ture of more than 50°C above the ambient temperatu-
re.
Before the appliance is connected check that the main
fuse and the domestic installation can support the load;
and that the power supply is properly earthed.
The manufacturers disclaim any responsibility
should these safety instructions not be carried out.
This appliance meets the requirements laid down in
EEC Directive No. 89/336 relating to the suppression
of radio and TV interferences.
FuseModels
Lower oven
rating
Upper oven
rating
Cable cross
section mm
2
and type of the cable
ZBD 903 3580 W 2825 W
6 mm
2
Type 6242Y
30 A.
For UK use only
FuseModels
Lower oven
rating
Upper oven
rating
Cable cross
section mm
2
and type of the cable
ZBD 903 3580 W 2825 W 4 mm
2
HO7 RR-F 30 A.
For Europe use