User manual

Daily use
Warning! Refer to the Safety chapters.
Ignition of the burner
Warning! Be very careful when you use
open fire in kitchen environment.
Manufacturer decline any responsibility in case
of misuse of the flame
Always light the burner before you put
cookware.
Lightning the burner:
1. Push the control knob down and turn it
counterclockwise to the maximum position (
).
2. Keep the control knob pushed for equal or
less than 10 seconds to let the thermocou-
ple warm up. If not, the gas supply will be
interrupted.
3. Adjust the flame after it is regular.
If the burner does not light after some tries,
check if the crown and its cap are in cor-
rect positions.
A
B
C
D
A
B
C
D
A) Burner cap
B) Burner crown
C) Ignition candle
D) Thermocouple
Warning! Do not keep the control knob
pushed for more than 15 seconds.
If the burner does not light after 15 seconds,
release the control knob, turn it into off position
and try to light the burner again after minimum 1
minute.
Important! In the absence of electricity you
can ignite the burner without electrical device;
in this case approach the burner with a flame,
push the relevant knob down and turn it
counter-clockwise to maximum gas release
position.
If the burner accidentally goes out, turn the
control knob to the off position and try to
light the burner again after minimum 1 minute.
The spark generator can start automatically
when you switch on the mains, after instal-
lation or a power cut. It is normal.
Turning the burner off
To put the flame out, turn the knob to the sym-
bol
.
6
www.zanussi.com