load > 1 kohm.
C34 NTHERM_L Negative of left traction motor temperature sensor.
C35 PTHERM_L Left traction motor temperature signal.
6.2 Connectors of the logic - "Dualac2&hp" and "Dualac2&hp
Power"
A1 CAN_H High level CANBUS.
A2 CANT_H CANBUS termination output, 120 ohm internally
connected to CAN_H. Connect to CAN_L_OUT to
insert the termination.
A3 CAN_POS Positive of CAN circuit; to be used in case of
optoisolated CANBUS.
A4 CAN_L_OUT Low level CANBUS: to be used as repetition for
CAN_L line or to be connected to CANT_H to insert
termination resistance.
A5 CANT_L CANBUS termination output, 120 ohm internally
connected to CAN_L. Connect to CAN_H_OUT to
insert the termination.
A6 CAN_L Low level CANBUS.
A7 CAN_H_OUT High level CANBUS: to be used as repetition for
CAN_H line or to be connected to CANT_L to insert
termination resistance.
A8 CAN_NEG Negative of CAN circuit, to be used in case of
optoisolated CANBUS.
B1 PCLRXD Positive serial reception.
B2 NCLRXD Negative serial reception.
B3 PCLTXD Positive serial transmission.
B4 NCLTXD Negative serial transmission.
B5 GND Negative console power supply.