+BTF Positive of battery before power fuse, must be
connected to positive cable coming from LC
contact.
Um; Vm; Wm Connection bars of the three right motors
phases; follow this sequence and the indication
on the motor.
Us; Vs; Ws Connection bars of the three left motors phases;
follow this sequence and the indication on the
motor.
-P Output of pump motor chopper.
+P Pump chopper positive, if the power fuse is not
present, the positive cable coming from LC
contact must be connected to this power
connection; also the pump motor positive cable
must be connected to this power connection.
+BPF Pump chopper positive before power fuse, must
be connected to positive cable coming from LC