AE9ZP0BD - DUALAC2/&HP/POWER - User Manual Page - 37/89
+BTF Positive of battery before power fuse, must be
connected to positive cable coming from LC contact.
Um; Vm; Wm Connection bars of the three right motors phases;
follow this sequence and the indication on the motor.
Us; Vs; Ws Connection bars of the three left motors phases; follow
this sequence and the indication on the motor.
-P Output of pump motor chopper.
+P Pump chopper positive, if the power fuse is not
present, the positive cable coming from LC contact
must be connected to this power connection; also the
pump motor positive cable must be connected to this
power connection.
+BPF Pump chopper positive before power fuse, must be
connected to positive cable coming from LC contact.