VACC MIN and VACC MAX are values programmable by the "Program
Vacc" function.
13) ADJUSTMENT#1 BDI
It adjusts the upper level of the battery discharge table.
14) ADJUSTMENT#2 BDI
It adjusts the lower level of the battery discharge table.
15) MAIN CONT. VOLTAGE
This parameters adjusts the Line contactor coil voltage (PWM output C26).
16) AUX OUTPUT VOLTAGE
This parameters adjusts the Electric brake coil voltage (PWM output C28).
17) LOAD HM FROM MDI
When set On, the HourMeter of the Controller is transferred and recorded on
the HourMeter of the Standard MDI (connected on the Serial Link).
18) CHECK UP DONE
Turn it ON when the required Maintenance service has been executed to
cancel the CHECK UP NEEDED warning.
19) CHECK UP TYPE
It specifies the handling of the CHECK UP NEEDED warning:
- NONE: No CHECK UP NEEDED warning.
- OPTION #1: CHECK UP NEENED warning shown on the hand set and
MDI after 300 hours.
- OPTION #2: Equal to OPTION#1 but speed reduction after 340 hours.