User manual

AE9ZP0BD - DUALAC2/&HP/POWER - User Manual Page - 65/89
8.6 Programming console functions
8.6.1 "Dualac2" and "Dualac2 Power"
- Functional configuration (see 8.4)
- Parameter programming (see 8.5)
- Tester: user can verify the state of the following parameters:
MASTER SLAVE
motor voltage (%) motor voltage (%)
frequency (Hz) frequency (Hz)
encoder (Hz) encoder (Hz)
slip value (Hz) slip value (Hz)
current rms (A) current rms (A)
temperature (°C) temperature (°C)
temperature #1(°C) voltage booster (%)
temperature #2(°C) battery voltage (V)
accelerator (V) seat switch (ON/OFF)
steer angle (°) forward switch (ON/OFF)
int. wheel cutback (%) backward switch (ON/OFF)
forward switch (ON/OFF) enable switch (ON/OFF)
backward switch (ON/OFF)
enable switch (ON/OFF)
seat switch (ON/OFF)
backing switch (ON/OFF)
cutback switch (ON/OFF)
brake switch (ON/OFF)
exclusive hydro (ON/OFF)
brakepedal pot. (%)
handbrake (ON/OFF)
voltage booster (%)
battery voltage (V)
battery charge (%)
hours-meter
- Save function (for storing data) --> only with Pc-console.
- Restore function (for downloading parameters to another controller) --> only
with Pc-console.
- Display of the last 5 alarms including hour-meter value and temperature at
the moment of the alarm.
- Accelerator range programming.
Records the minimum and maximum useful accelerator stroke values for
both direction of running.
- See the console manual for a detailed description of function and
parameters.
8.6.2 "Dualac2&hp" and "Dualac2&hp Power"
- Functional configuration (see 8.4)
- Parameter programming (see 8.5)
- Tester: user can verify the state of the following parameters:
MASTER SLAVE
motor voltage (%) motor voltage (%)
frequency (Hz) frequency (Hz)
encoder (Hz) encoder (Hz)
slip value (Hz) slip value (Hz)