User manual

Page - 70/89 AE9ZP0BD - DUALAC2/&HP/POWER - User Manual
7) VOLTAGE BOOSTER
This is the booster of the voltage supplied to the motor in load condition; it is
expressed in a percentage of the full voltage.
8) BATTERY VOLTAGE
Level of battery voltage measured at the input of the key switch.
9) SEAT SWITCH
The level of the Seat Microswitch digital input.
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch opened.
10) FORWARD SWITCH
The level of the Forward direction digital input FW.
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch opened.
11) BACKWARD SWITCH
The level of the Reverse direction digital input BW.
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch opened.
12) ENABLE SWITCH
The level of the Enable digital input:
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.
8.9.3 "Dualac2&hp" and "Dualac2&hp Power" – Master
See chapter 8.9.1.
8.9.4 "Dualac2&hp" and "Dualac2&hp Power" - Slave
1) MOTOR VOLTAGE
This is the voltage supplied to the motor by the inverter; it is expressed as a
percentage of the full voltage (which depends of the battery voltage).
2) FREQUENCY
This is the frequency of the voltage and current supplied to the motor.
3) ENCODER
This is the speed of the motor, expressed in the same unit of the frequency;
this information comes from the speed sensor.
4) SLIP VALUE
This is the difference of speed between the rotating field and the shaft of the
motor, expressed in the same unit of the frequency.
5) CURRENT RMS
Root Mean Square value of the motor current.
6) TEMPERATURE
The temperature measured on the aluminium heat sink holding the MOSFET
devices.
7) VOLTAGE BOOSTER
This is the booster of the voltage supplied to the motor in load condition; it is
expressed in a percentage of the full voltage.
8) BATTERY VOLTAGE
Level of battery voltage measured at the input of the key switch.
9) SEAT SWITCH
The level of the Seat Microswitch digital input.
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.
10) FORWARD SWITCH
The level of the Forward direction digital input FW.
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.