User manual

AE9ZP0BD - DUALAC2/&HP/POWER - User Manual Page - 71/89
11) BACKWARD SWITCH
The level of the Reverse direction digital input BW.
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.
12) ENABLE SWITCH
The level of the Enable digital input:
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.
13) LIFTING CONTROL
Voltage of the lifting potentiometer (CPOT LIFT).
14) LIFTING SWITCH
Status of the lifting switch.
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.
15) 1ST SPEED SWITCH
Status of the first speed switch of the hydraulic system.
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.
16) 2ND SPEED SWITCH
Status of the second speed switch of the hydraulic system.
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.
17) 3RD SPEED SWITCH
Status of the third speed switch of the hydraulic system..
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.
18) 4TH SPEED SWITCH
Status of the fourth speed switch of the hydraulic system..
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.
19) 5TH SPEED SWITCH
Status of the fifth speed switch of the hydraulic system..
- ON / +VB = input active, switch closed.
- OFF / GND = input non active, switch open.
20) PUMP CURRENT
Current of the pump motor.
21) PUMP VOLTAGE
Voltage between pump chopper output and -BATT.
22) PUMP TEMPERATURE
Temperature of pump chopper power section.