User manual

Page - 74/89 AE9ZP0BD - DUALAC2/&HP/POWER - User Manual
10) When you have finished looking at the Alarms,
press OUT to exit the ALARMS menu.
' ' '
' % '
11) The Display will ask “CLEAR LOGBOOK?”.
CLEAR LOGBOOK?
YES=ENTER NO=OUT
12) Press ENTER for yes, or OUT for NO.
' % '
' ' '
' ' '
' % '
13) Press OUT to return to the Opening Zapi
Display.
' ' '
' % '
9.3 Description of Console Program Vacc function
This function looks for and remembers the minimum and maximum potentiometer
wiper voltage over the full mechanical range of the pedal. It enables
compensation for non symmetry of the mechanical system between directions.
The operation is performed by operating the pedal after entering the PROGRAM
VACC function.
Flow Chart showing how to use the PROGRAM VACC function of the Digital
Console:
1) Opening Zapi Display.
DUALAC2 ZAPI V0.0
48V 350A 00000
2) Press ENTER to go into the General Menu.
' % '
' ' '
3) The Display will show:
MAIN MENU
PARAMETER CHANGE
4) Press ROLL UP or ROLL DOWN button until
PROGRAM VACC appears on the display.
% ' '
% ' '
5) The Display will show:
MAIN MENU
PROGRAM VACC
6) Press ENTER to go into the PROGRAM VACC
routine.
' % '
' ' '
7) The Display will show the minimum and
maximum values of potentiometer wiper output.
Both directions can be shown.
VACC SETTING
4.8 4.8
8) Press ENTER to clear these values.
Display will show 0.0.
' % '
' ' '
9) Select Forward Direction, close any interlock
switches that may be in the system.
MIN VACC MAX
0.0 - 0.0