User manual

AE9ZP0BD - DUALAC2/&HP/POWER - User Manual Page - 79/89
Co
de
ALARM
STRING
Ma
ster
Slave
CONTROLLER
STATUS
DESCRIPTION
Condition that has to
occur to come out
from alarm status
Init Stby Motor
running
246 MASTER KO X X X X Alarm: Slave µC
detects a Master
µC malfunctioning
or a mismatch
between inputs
status and Master
commands (via
Canbus)
To recycle the key
250 INPUT
MISMATCH
X X X X Alarm: Slave µC
has detected a
mismatch
between inputs
status and the
input status
transmitted via
Canbus by
Master µC
To recycle the key
253 AUX OUTPUT
KO
X X X X Alarm: EB coil
driver shorted or
open
-If the alarm is present
in Init status, remove
the alarm cause
-If the alarm has
occurred in stby or
running mode, it is
necessary to remove
alarm cause and to
activate traction
request
13 EEPROM KO X X X X X Warning: Eeprom
fault, controller
will use default
parameters
To remove Warning
cause
61 HIGH
TEMPERA-
TURE
X X X X X Warning: Master
or Slave or both
temperature
higher than 75°C
To remove Warning
cause
65 MOTOR
TEMPERA-
TURE
X X X X X Warning: Master
or Slave or both
motors
temperature high
To remove Warning
cause
66 BATTERY
LOW
X X X X Warning: battery
charge level
below 20%
To remove Warning
cause