User manual

Page - 80/89 AE9ZP0BD - DUALAC2/&HP/POWER - User Manual
Co
de
ALARM
STRING
Ma
ster
Slave
CONTROLLER
STATUS
DESCRIPTION
Condition that has to
occur to come out
from alarm status
Init Stby Motor
running
78 VACC NOT
OK
X X X Warning:
accelerator signal
(CPOT) voltage
higher than
VACC MIN +1V
while the traction
enable switch is
open
To remove Warning
cause
79 INCORRECT
START
X X X X Warning: wrong
traction request
sequence
To remove Warning
cause
80 FORWARD +
BACKWARD
X X X X Warning: forward
and reverse
inputs are both
active
To remove Warning
cause
249 THERMIC
SENSOR KO
X X X X X Warning: Master
or slave
temperature
sensor is out of
range
To remove Warning
cause
251 WAITING
FOR NODE#4
X X X X Warning: Master
µC signals that
Slave µC is in
alarm status
To remove Warning
cause
251 WAITING
FOR NODE#3
X X X X Warning: Slave
µC signals that
Master µC is in
alarm status
To remove Warning
cause
247 NO CAN
MESSAGE #4
X X X X Alarm: Master
has lost Can
communication
with the Slave
To remove Warning
cause
247 NO CAN
MESSAGE #3
X X X X Alarm: Slave has
lost Can
communication
with the Master
To remove alarm
cause
244 SLAVE
WARNING
X X X X Warning: Slave
µC has a warning
To remove Warning
cause
250 HANDBRAKE X X X Warning: the
operator try to
travel with the
handbrake active
To remove Warning
cause