Specifications

2=CA
3.4 DESCRIPTION OF CONNECTORS - STANDARD VERSION
A1 NLC Negative of main contactor coil.
A2 PLC , PEB Positive of main contactor coil and electromechanical brake coil.
A3 NBRAKE Output for driving the electromechanical brake coil; drives the load
to -Batt. Maximum current : 3A.
A4 NPC Negative of pump contactor coil.
A5 PPC , PEV Positive of pump contactor coil and lowering electrovalve coil.
A6 NEV Negative of the lowering electrovalve coil.
A7 CAN-L Low level CAN-BUS voltage I/O.
A8 NPOTB -Batt.
A9 ENCODER Incremental ENCODER (see chapter 3.6).
A10 ENCODER Incremental ENCODER (see chapter 3.6).
A11 HM Output for driving an hourmeter; when the hourmeter is active this
output provides a +Batt signal; 3A maximum current.
A12 -BATT -Batt.
A13 SR1 Speed reduction 1 input. Active low (switch opened).
A14 SR2 Speed reduction 2 input. Active low (switch opened).