Specifications

2=CA '
8 AUX OUTPUT #1
- BRAKE: output A3 drives an electromagnetic brake coil (see also the
table below).
- HYDRO CONT.: the inverter manages an hydraulic steering function when the
direction input or brake pedal input are active or a movement
of the truck is detected.
- EX. HYDRO: output A3 drives an hydraulic steering function when the
exclusive hydro input is active.
9 PEDAL BRAKING
- ANALOG: Option "Set input #4" programmed "Belly":
the mechanical brake pedal has a potentiometer installed.
When the accelerator is released and the pedal brake is
pushed the inverter performs an electrical braking whose
intensity is proportional to the brake pedal potentiometer. The
minimum intensity is established by the "Release braking"
parameter, when the brake pedal is slightly pressed (brake
potentiometer at the minimum). The maximum intensity is
established by the "Pedal braking" parameter when the brake
pedal is fully pressed (brake potentiometer at the maximum).
In the middle positions, the electrical braking intensity is a
linear function between minimum and maximum intensity.
Option "Set input #4" programmed "Brake":
the mechanical brake pedal has a switch and a potentiometer
installed. When the accelerator is released and the pedal
brake is pushed the inverter performs an electrical braking
whose intensity is proportional to the brake pedal
potentiometer. The minimum intensity is established by the
"Release braking" parameter, when the brake pedal is
slightly pressed (brake switch closed but brake potentiometer
at the minimum). The maximum intensity is established by the
"Pedal braking" parameter when the brake pedal is fully
pressed (brake potentiometer at the maximum). In the middle
positions, the electrical braking intensity is a linear function
between minimum and maximum intensity.
- DIGITAL: The truck does not have a potentiometer installed on the
mechanical brake pedal, but only a microswitch; when the
accelerator pedal is released and the brake pedal is pushed
(brake switch closed), the inverter performs an electrical
braking following "Pedal braking" parameter.
- NONE: Means that there aren't any switch or potentiometer installed
on the brake.
10 QUICK INVERSION
- NONE The quick inversion function is not managed.
- TIMED The quick inversion function is timed.
- BELLY The quick inversion function is managed but not timed.