Specifications

2=CA"
18 MAX VALVE 1: this parameter determines the maximum voltage
applied on the electrovalve 1 when the position of the
potentiometer is at the maximum. If the electrovalve 1
is programmed like a On/Off valve (see the
configuration chapter) this parameter determines the
voltage applied on the electrovalve coil.
19 MAX VALVE 2: this parameter determines the maximum voltage
applied on the electrovalve 2 when the position of the
potentiometer is at the maximum. If the electrovalve 2
is programmed like a On/Off valve (see the
configuration chapter) this parameter determines the
voltage applied on the electrovalve coil.
20 VALVE 3 VOLTAGE: this parameter determines the voltage applied on the
electrovalve 3.
21 VALVE 4 VOLTAGE: this parameter determines the voltage applied on the
electrovalve 4.
22 V1 OPENING RAMP this parameter determines the ramp of voltage
applied on the electrovalve 1 in the opening transition
(if proportional); this is the time necessary to go from
the minimum to the maximum voltage. If the
electrovalve is programmed like an On/Off valve this
parameter is not effective.
23 V2 OPENING RAMP this parameter determines the ramp of voltage
applied on the electrovalve 2 in the opening
transition. (if proportional); this is the time necessary
to go from the minimum to the maximum voltage. If
the electrovalve is programmed like an On/Off valve
this parameter is not effective.
24 V1 CLOSING RAMP this parameter determines the ramp of voltage
applied on the electrovalve 1 in the closing transition
(if proportional); this is the time necessary to go from
the maximum to the minimum voltage. If the
electrovalve is programmed like an On/Off valve this
parameter is not effective.
25 V2 CLOSING RAMP this parameter determines the ramp of voltage
applied on the electrovalve 2 in the closing transition
(if proportional); this is the time necessary to go from
the maximum to the minimum voltage. If the
electrovalve is programmed like an On/Off valve this
parameter is not effective.