Specifications

2=CA"!
4.7 PROGRAMMING CONSOLE FUNCTIONS
- Functional configuration (see 4.1 , 4.2 , 4.3 , 4.4)
- Parameter programming (see 4.5 , 4.6)
- Tester: the user can verify the state of the following parameters:
STANDARD Version MDI PRC Version
battery voltage (V) battery voltage (V)
motor voltage (%) motor voltage (%)
voltage booster (%) voltage booster (%)
frequency (Hz) frequency (Hz)
encoder (Hz) encoder (Hz)
slip value (Hz) slip value (Hz)
cos fi cos fi
current rms (A) current rms (A)
battery current (A) battery current (A)
battery charge (A) battery charge (A)
temperature (°C) temperature (°C)
accelerator (V) accelerator (V)
brake pedal pot (%) lifting control (V)
lifting switch (ON/OFF) lifting switch (ON/OFF)
descent switch (ON/OFF) descent switch (ON/OFF)
forward switch (ON/OFF) forward switch (ON/OFF)
backward switch (ON/OFF) backward switch (ON/OFF)
seat switch (ON/OFF) seat switch (ON/OFF)
Hard&Soft (ON/OFF) Hard&Soft (ON/OFF)
quick inversion(ON/OFF) quick inversion(ON/OFF)
cutback switch (ON/OFF) cutback switch (ON/OFF)
cutback switch 2 (ON/OFF) digital input #1 (ON/OFF)
cutback switch 3 (ON/OFF) digital input #2 (ON/OFF)
- Save function (for storing data)
- Restore function (for loading parameters on another chopper)
- Display of the last 5 alarms including hour-meter value and temperature at the mo-
ment of the alarm.
- Accelerator range programming: records the minimum and maximum useful accelera-
tor stroke values for both direction of running.
- See the console manual for a detailed description of function and parameters.