Specifications

EM 220
Rev. 1.00
- 28 -
Mobile Printer Command Manual
<Function 1> BS ^ E pL pH fn (fn=1)
[Format]
[Range]
[Description]
ASCII BS ^ E pL pH fn
Hex 08 5E 45 pL pH fn
Decimal 08 94 69 pL pH fn
(pL + pH x 256) = 1 (pL=1, pH=0)
fn=1
Enter the user setting mode and notifies that the mode has changed.
Hexadecimal Decimal Number of Data
Header 37H 55 1 byte
Flag 20H 32 1 byte
NUL 00H 0 1 byte
The following commands are enabled in the user setting mode.
<Function 2> through
<Function 2> BS ^ E pL pH fn d1 d2 d3 (fn=2)
[Format]
[Range]
[Description]
ASCII GS ( E pL pH fn
Hex 1D 28 45 pL pH fn
Decimal 29 40 69 pL pH fn
(pL + pH x 256) = 1 (pL=1, pH=0)
fn=2
Ends the user setting mode and performs a software reset. Therefore, the
printer clears the receive and print buffers, and resets all (downloaded bit
images, macros, and the print mode) to the mode that was in effect at
power on.
This function code (fn=2) is enabled only in the user setting mode.