Specifications

EM 220
Rev. 1.00
- 34 -
Mobile Printer Command Manual
Sets the configuration item for the serial interface specified by d1..dk
Setting Oder Configuration item
1 Transmission speed
2 Parity
3 Flow control
4 Data length
Example : When defining 19200 bps and Noparity, DTR/DSR, 8bit Data
length : d1~dk(Hexadecimal = 32H,30H,30H,30H,30H,38H
/Decimal= 49,57,50,48,48,48,48,56)
Baud rate is specified by d1~dk-3 as follows:
d1~dk-3 Function
“115200” Baud rate 115200
“57600” Baud rate 57600
“38400” Baud rate 38400
“19200” Baud rate 19200
“9600” Baud rate 9600
“4800” Baud rate 4800
“2400” Baud rate 2400
Parity is specified by dk-2 as follows:
dk-2 Function
48 Select no parity
49 Select odd parity
50 Select even parity
Flow control is specified by dk-1 as follows:
dk-1 Function
48 Select Flow control DTR/DSR
49 Select Flow control XON/XOFF
Data Length(a=4) is specified by dk as follows:
dk Function
55 Select 7bit length
56 Select 8bit length