Specifications
EM 220
Rev. 1.00
- 43 -
Mobile Printer Command Manual
<Function 067> GS ( k pL pH cn fn n (fn=67)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 30 43 n
Decimal 29 40 107 3 0 48 67 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=67
2 ≤ n ≤ 3
n=3
Specifies the width of a module of PDF417 symbol.
▪ Settings of this function affect the processing of Functions 081 and 082.
▪ The setting unit differs, depending on the printer models.
▪ This function is effective until ESC @ is executed, the printer is reset, or
the power is turned off.
<Function 068> GS ( k pL pH cn fn n (fn=68)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 30 44 n
Decimal 29 40 107 3 0 48 68 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=68
2 ≤ n ≤ 8
n=3
Specifies the module height of PDF417 symbol.
- Specify the height to [a module width x n].
▪ Settings of this function affect the processing of Functions 081 and 082.
▪ This function is effective until ESC @ is executed, the printer is reset, or
the power is turned off.