Specifications

EM 220
Rev. 1.00
- 43 -
Mobile Printer Command Manual
<Function 067> GS ( k pL pH cn fn n (fn=67)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 30 43 n
Decimal 29 40 107 3 0 48 67 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=67
2 n 3
n=3
Specifies the width of a module of PDF417 symbol.
Settings of this function affect the processing of Functions 081 and 082.
The setting unit differs, depending on the printer models.
This function is effective until ESC @ is executed, the printer is reset, or
the power is turned off.
<Function 068> GS ( k pL pH cn fn n (fn=68)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 30 44 n
Decimal 29 40 107 3 0 48 68 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=68
2 n 8
n=3
Specifies the module height of PDF417 symbol.
- Specify the height to [a module width x n].
Settings of this function affect the processing of Functions 081 and 082.
This function is effective until ESC @ is executed, the printer is reset, or
the power is turned off.