Specifications

EM 220
Rev. 1.00
- 53 -
Mobile Printer Command Manual
<Function 265> GS ( k pL pH cn fn n1 n2 (fn=65)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn n1 n2
Hex 1D 28 6B 04 00 32 41 n1 0
Decimal 29 40 107 3 0 50 65 n1 0
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=50
fn=65
50 n 52
n = 50
Maxi Code Mode Settings
n Function
50 Mode 2 Setting
51 Mode 3 Setting
52 Mode 4 Setting
The setting of this function impacts <Function 281> and <Function 282>.
This function is effective until ESC @ is executed or the printer power is
turned off.
<Function 280> GS ( k pL pH cn fn m d1...dk (fn=80)
[Format]
[Range]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn m d1...dk
Hex 1D 28 6B pL pH 32 50 30 d1...dk
Decimal 29 40 107 pL pH 5 50 48 d1...dk
4 (pL + pH x 256) 141 (4 pL 141, 0 pH 0)
cn=50
fn=80
m=48
0 d 255
k = (pL + pH x 256) – 3
Saves MAXI CODE symbol data in the symbol storage area
Execution of this command saves data to the data storage area and
executes Functions 281 and 282. Following execution of Functions 281
and 282, the data remains saved in the symbol storage area.
k byte represents the symbol data of d1...dk.
The setting impacts the function until the following actions are carried out:
- Execution of Function 280
- Execution of ESC @
- Turning off of printer power