<Function 380> GS ( k pL pH cn fn m d1...dk (fn=80)
[Format]
[Range]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn m d1...dk
Hex 1D 28 6B pL pH 32 50 30 d1...dk
Decimal 29 40 107 pL pH 5 50 48 d1...dk
0 ≤ (pL + pH x 256) ≤ 3116 (0≤ pL ≤255, 0 ≤ pH ≤13)
cn=51
fn=80
m=48
0 ≤ d ≤ 255
k = (pL + pH x 256) – 3
Saves DATAMATRIX symbol data to the symbol storage area
▪ Execution of this command saves data to the data storage area and
executes Function 281. Following execution of Function 281, the data
remains saved in the symbol storage area.
▪ k byte represents the symbol data of d1...dk.
▪ The setting impacts the function until the following actions are carried out:
- Execution of Function 380
- Execution of ESC @
- Turning off of printer power