Owner`s manual

ExternalControlDeviceSetup
25. PIP Input Select (Command2:y)
To select input source for sub picture in PIP mode.
Transmission
[[k][y][ ][Set Ig][ ][Data][Cr] ]
Data 0 :RGB 4 :DVI
1 " Component 5 " TV
2 : Video 6 : Video (Exp.)
3 : S-Video
Acknowledgement
[[y][ ][Set ID][ ][OK][Data][x]
26. Abnormal State (Command2:z)
To recognize an abnormal state.
Transmission
[[k][z][ ][Set Ig][ ][FF][Cr] ]
Data FF:Read
Acknowledgement
I[z][ ][Set ID][ ][OK][Data][x]
Data
I
O: Normal (Power on and signal exist)
1 : No signal (Power on)
2: Turn the monitor off by remote control
3: Turn the monitor off by sleep time function
4: Turn the monitor off by RS-232C function
5: 5V down
6: AC down
7: Turn the monitor off by Fan Alarm function
8: Turn the monitor off by off time function
9: Turn the monitor off by auto off function
a: Turn the monitor off by AV board defect
27. ISM Method (Command2:p)
To avoid having a fixed image remain on screen.
Transmission
_][p][ ][Set ID][ ][Dafal[Cr] J
Data O: Normal 2: Orbiter
1: White wash 3: Inversion
Acknowledgement
[[p][ ][Set ID][ ][OK][Data][x] J
28. Low Power (Command2:q)
To control the low power function on/off.
Transmission
_][q][ ][Set Ig][ ][gata][Cr] J
Data O: Low power off
1: Low power on
Acknowledgement
[[q][ ][Set ID][ ][OK][Data][x] J
38 Plasma iV
29. Orbiter Time Setting (Command2:r)
To adjust orbiter operation time term.
Transmission
_][r][ ][Set Ig][ ][gata][Cr] J
Data Min: 1 -- Max: FE
Acknowledgement
[[r][ ][Set ID][ ][OK][Data][x]
30. Orbiter Pixel Setting (Command2:s)
To adjust pixel number in orbiter function.
Transmission
_][s][ ][Set ID][ ][Datal[Cr ] J
Data Min:0_Max:9
Acknowledgement
[[s][ ][Set ID][ ][OK][Data][x]
31. Picture Size Setting for Double Window
mode (Command2 :t)
To adjust main window size in Double Window mode.
Transmission
[u][tl[][SefID][ ][Data][Cr] J
Data Min: 0 ~ Max: 64
Refer to 'Real data mapping1'. See page 35.
Acknowledgement
[[t][ ][Set ID][ ][OK][Data][x] J
32. Auto Configure (Command2:u)
To adjust picture position and minimize image shaking
automatically. It works only in RGB (PC) mode.
Transmission
_][u][ ][Get ID][ ][Data][Cr] J
Data 1: To set
Acknowledgement
[[u][ ][Set ID][ ][OK][Data][x]