Use, Care, and Installation Guide www.zephyronline.com Okeanito CO K-E36SX CO K-E42SX CO K-E48SX Model number: Serial number: Date of Purchase: Sales Dealer: MAY07.0101 © Zephyr Corporation.
www.zephyronline.
2 3 INSTALLATION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting .................................................................. Specifications ....................................................... Internal Blower .................................................... Preparing Hood for External Blower .............. Mounting the Hood ............................................
www.zephyronline.com Important safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE TH E R IS K O F FIR E O R E LE C TR IC SHOC K, DO NOT USE TH IS FAN W ITH ANY S O LID-S TATE SPE E D CONTROL DEV IC E. WARNING TO RE DUCE TH E R IS K O F FIR E, E LE C TR IC SH O C K, O R INJU RY TO P E R SON S, O B S E RVE TH E FO LLO W ING: a. Use this unit only in the manner intended by the manufacturer, If you have questions, contact the manufacturer. b.
1 - Hood 1 - Baffle Filter (2 on 48” model) 2 - 50W 120V Halogen Light Bulbs GU-10 2 - 40W 120V Appliance Bulbs 1 - Utensil Rail 2 - Telescopic Duct Covers 1 - Ceiling Mounting Bracket (pre attached to duct cover) 1 - Wall Mounting Bracket 1 - HARDWARE PACKET 7 - 2” Wood Screws 7 - Anchors 7 - 1/2” Washers 4 - 1/2” Screws 5x15mm 4 - 10mm Washers 1 - SMALL HARDWARE PACKET 1 - T ool 3 - Short Set Screws (4 on 48” Model) 1 - HARDWARE PACKET, EXTERNAL BLOWER KIT 1 - 8” Collar 1 - External Blower Wiring Box with
Ins ta lla tion - Ductwork C a lcula tion S heet www.zephyronline.com Equivalent number length x used = Duct pieces Equivalent number length x used = Duct pieces Total Total 3 1/4” x 10” Rect., straight 1 Ft. x( ) = Ft. 6” Round 30 Ft. wall cap with damper x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6” Round, roof cap 30 Ft. x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6” round to 3 1/4” x 10” rect. transition 1 Ft. x( ) = Ft. 3 1/4” x 10” Rect. 90 0 elbow 15 Ft.
Min 32"-Max 52" Maximum mount height should be no higher than 36". It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency. 14 1/2" Min 96"-Max 124” Min 28"-Max 36" If available, also refer to range manufacturer's height clearance requirements and recommended hood mounting height above range.
Installation - Ducting www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics, or garages. All exhaust must be ducted to the outside. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or DuctTape.
10” 19 3/4” 16 5/8” 13 3/8” 14 1/2” LOGO CHENG DESIGN BY ZEPHIR 95° 11 7/8” 36”, 42”, 48” 22 5/8” 5" - 36" 8"- 42" 3 1/2"-48" 6" 15” 1/4” R 5/ 16 ” ” /8 7 3/8” 41 O R 41 1/32” 15 /32” 1“ 8 5/16” 9 3/16” 7 Installation - Specifications 19 3/4”
Ins ta lla tion - Interna l B lower www.zephyronline.com ATTENTION The following are intructions for installing internal blower model CBI-600. For instructions on preparing for external blower model CBE-1000 please turn to page “10”. Before installing, verify that motor spins freely. The internal blower kit consists of the blower and capacitor box with wiring. 1. Position blower as shown. 2. Att ach blower to flange as shown using the provided 1/2” 5x15mm screws with washers. 3.
6. Re-attach grounding screw to finish installation of capacitor box. Refer to Fig-A on previous page. 7. Attach short capacitor connector to blower connector. 8. Att ach long capacitor connector to control board connector. 9. Use plastic tie to hold wiring together. 10. Remove wood block Final view of internal blower install. Continue to page “12” for hood installation instructions. 9 Installation - Internal Blower 5. Remove existing grounding screw and attach grounding wire from capacitor box.
Ins ta lla tion - P repa ring E xterna l B lower www.zephyronline.com ATTENTION The following are intructions on preparing your hood for installation with external blower model CBE-1000. For instructions on installing internal blower model CBI-600 please turn to page “8”. NOTE: Please refer to the CBE-1000 manual for external blower mounting instructions. The external blower kit consists of an 8” collar, and external blower wiring box. The external blower is purchased separately. 1.
7. Secure cover to box with provided screw. 8. Attach connector from external blower wiring box to control board box connector inside hood. 9. Attach grounding wire from external blower wiring box to grounding screw of the junction box. Refer on Fig-A in diagram below . 10. Final view of external blower preparation Continue to page “12” for hood installation instructions. For external blower installation please refer to the manual included with the external blower.
www.zephyronline.com Installation - Preparing Hood Duct Cover Ceiling Bracket C/L Duct Cover Ceiling Bracket B C 21” 14 1/2” 7 1/2” A min 28” max 36” C/L C/L Attach screws to ceiling bracket 1. Measure from cooking surface to hood bottom, level and mark line A. 2. Plum and mark center line. 3. Mark mounting height, line B (14 1/2” from line A). This is the top of the hood. 4. Measure up, 7 1/2” from line A and mark mounting spread from C/L Line C. (21”) 5.
Ins ta lla tion - M ounting Hood Top gap between bracket and wall B C A Bottom Attach screws to both sides of the duct cove rs and secure to ceilingbracket. 10” Electrical 1. Place wall bracket on line C. Position top of wall bracket so it is even with the 21” mounting spread. Make sure bracket is attached to wall as shown in the diagram. The top of the wall bracket should have a gap between it and the wall. The bottom should be flush against the wall. Use (3) 2” wood screws to attach bracket to wall.
Ins ta lla tion - Atta ching Utens il R a il www.zephyronline.com Set screw Front Back 1. Attach utensil rail to hood canopy. A small hole has been pre-drilled into the canopy to provide a starting point to attach the first utensil rail post. After the first post is lined up with the hole, gently slide the rest of the rail onto the canopy. (note: be careful not to scratch the stainless steel when performing this step, this is why there is a starter hole). 2.
Features & Controls - Touch Controls & Features www.zephyronline.com 1 Blower On/Off 5 Display (Speed level, Delay Off Indicator, Filter Clean/Change) 6 Mood Light On/Off 2 Adjust 3 Speed Levels 4 Lights On/Off/Hold to Dim 3 15 Min Delay Off 1. Blower On/Off By pressing , the blower is switched On and Off. 2. Speed Selection The 3 speed levels are selected by pressing The display indicates level selected. to decrease and to increase speed level. 3.
Filter Clean Reminder: When flashes on display, the baffle filters installed are required to be cleaned. This will occur after every 30 hours of use. Clean Filters display flashes Re-setting Function: Reset the Filter Clean Reminder timer when filters are cleaned and re-installed (with hood off). Press and hold for approx. 5 seconds, the display will appear; hold for approximately 5 seconds until on display disappears .
M a intena nce - C lea ning www.zephyronline.com Surface Maintenance: Clean periodicallywith hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel i h will scratch and damage surface. wool/scouring pads whic For heavier soil use liquiddegreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, topolish and buff out the stainless luster and grain. Always scrub lightlyy with clean cotton cloth, and with the grain.
CA UTION: Light bulbs become extremely hot when turned on. DO NOT touch bulbs until switched off and cooled. Touching hot bulbs may cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip together, the light socket will now protude from the hood allowing you to remove the bulb.
Trouble S hooting www.zephyronline.com Issue Cause What to do After installation, the unit doesn’t work? 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3.
www.zephyronline.
Warranty www.zephyronline.com TO OBTAIN SERVICE UNDER WARRANTY or any Service Related Questions, please call: 1-888-880-8368 Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty. TO OBTAIN SERVICE UNDER WARRANTY: You must present proof of original purchase date. Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.