Hood User Manual

The following instructions are for installing the internal blower.
CAUTION: To reduce the risk of fire and electric shock, install this rangehood
only with internal blower models CBI-290A or CBI-600A.
For external and in-line blower prepara-
tion please turn to page 15.
1.Remove the 6” round metal knockout
plate from the blower plate by using
a flat head screwdriver. See.Fig.1
2. Remove the (6) screws securing the
blower plate to the blower housing
and remove blower plate. See. Fig.2
3. Install internal blower into blower
plate and secure using (4) screws in-
cluded with the blower. See Fig.3
4. Secure capacitor box connected to
the provided cable to the blower
plate using (2) screws included with
the blower. See.Fig.4
5. Secure Green/Yellow ground wire
connected to the cable to the provi-
ded capacitor to blower plate.Fig.5
6. Attach the 6 pin male molex connec-
tor from blower wire to the 6 pin fe-
male molex connector located inside
the blower housing. See Fig.6
Installation - Internal Blower
- 13 -