Layers Wall Surface Wall ALA - M90ABX ALA - M90AWX ALA - E42ABX ALA - E42AWX ASU - M90ASX ASU - E42ASX Edge Wall Duo Wall AED - M90ASX ADU - M90ASX RANGE HOOD - Installation instructions www.zephyronline.
www.zephyronline.com HOTTE PER CUISINE - Notice d’utilisation...Pag. 27 CAMPANA EXTRACTORA - Manual de utilización...Pag. 53 CAPPA ASPIRANTE - istruzioni per l’uso...Pag.
LIST OF MATERIALS...........................................................................................................pag. 7 DUCTING CALCULATION SHEETS.............................................................................pag. 11 HOOD SPECIFICATION..................................................................................................pag. 12 INSTALLATION - INTERNAL BLOWER.....................................................................................pag.
Safety instructions www.zephyronline.com IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Take care when using cleaning agents or detergents.
WARNING – TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: A. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out mmediately, EVACUATE AND CALL THE FIRE DEPARTMENT. B. NEVER PICK UP A FLAMING PAN – You may be burned. C. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result. D. Use an extinguisher ONLY if: 1.
Safety instructions www.zephyronline.com through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D.
List of Materials Models: ALA-M90ABX / ALA-M90AWX / ALA-E42ABX / ALA-E42AWX Duct Cover Bracket Duct Covers Blower Housing Electrical Junction Box Glass Range Hood Body Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° A M4 1+1 B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 D 1/4" x 2-3/4" 6 -7-
List of Materials www.zephyronline.
List of Materials Models: AED M90ASX Duct Covers Duct Cover Bracket Control Range Hood Body Light Panel Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° A M4 1+1 B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 D 1/4" x 2-3/4" 6 -9-
List of Materials www.zephyronline.
Ducting Calculation Sheet Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet.
Hood Specifications www.zephyronline.
side of hood front of hood top of hood - 13 - Hood Specifications Models: ASU-M90ASX / ASU-E42ASX
Models: AED-M90ASX side of hood front of hood top of hood 11-1/4" 35-3/8" Wood Trim Dimensions 5/8" Thickness - 14 - 19-11/16" 12-1/16" 10-1/16" Hood Specifications www.zephyronline.
side of hood front of hood top of hood 11-1/4" 35-3/8" Wood Trim Dimensions 1-5/8" Thickness - 15 - 19-11/16" 10-1/16" 12-1/16" Hood Specifications Models: ADU-M90ASX
Installation - Internal Blower www.zephyronline.com The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fire and electric shock, install this rangehood only with internal blower models MT-020 provided with the kit cod CBI-600A. For external and in-line blower preparation please turn to page 18. 1.Remove the 6” round metal knockout plate from the blower plate by using a flat head screwdriver. See.Fig.1 2.
7. Install blower and blower plate into blower housing by following the reverse instructions from step 2 then use the screws provided to complete installation. (Tot. 14 type B). See Fig.7 8. Connect 9 pin male molex connector from blower wire to 9 pin female molex connector on the capacitor wire. See Fig.8 WARNING! Place electrical wiring inside the motor housing. The hood is now ready to be installed on the wall. - 17 - Installation - Internal Blower 6.
Installation - External & In-Line Blower Preparation www.zephyronline.com The following instructions are for preparing the hood for use with an external or in-line blowers models CBE-1000 or PBN-1000A. CAUTION: To reduce the risk of fire and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A. For internal blower instructions please turn to page 16. 1. Remove the (6) screws securing the blower plate to the blower housing and remove blower plate. See.Fig.1 2.
7. Feed remote blower wire harness through remote blower junction box cover and Connect the wires with those inside the junction box. See Fig. 7 Note: Carry out the power supplly connection in accordance with the national electric code, ANSI/NFPA 70-1999. 8.Secure cover to junction box using (2) screws. Note1: A cable lock (not included) may be required by local codes. Please review local codes for more information. 9.
Installation - Ducting Options www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certif ed Silver Tape or Duct Tape.
The range hood must be installed at a minimum height of 24 inches (61cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot air or fumes from another appliance. Before proceeding with the assembly instructions remove the decorative mesh filters so that the range hood is esier to handle. Min 24" - Max 36" MOUNTING TO THE WALL 1.
Installation - Power Supply Connection www.zephyronline.com GENERAL • Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations. POWER SUPPLY CONNECTION For connection to the power supply refer to the following: 1. Lift the bottom part of the duct cover and secure it carefully using adhesive tape. 2. Remove the power supply cover by undoing the (2) screws Fig. 11. 3.
Models: ALA-M90ABX / ALA-M90AWX / ALA-E42ABX / ALA-E42AWX / AEDM90ASX / ADU-M90ASX 1. Install the electrical wiring and test hood for functions prior to installing the duct covers. 2. If using hood in air recirculating mode make sure to install the air diverter plate prior to mounting the duct covers. See the manual included with the recirculating kit for more instructions. 3.
Installation - Mounting the Duct Cover www.zephyronline.com Models: ASU-M90ASX and ASU-E42ASX 1. Install the electrical wiring and test hood for functions prior to installing the duct covers. 2. If using hood in air recirculating mode make sure to install the air diverter plate prior to mounting the duct covers. See the manual included with the recirculating kit for more instructions. 4. Secure duct cover bracket to top of wall just below the ceiling using (2 type D) screws provided. See Fig. 12 5.
• It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of maintenance. • The decorative mesh filters capture the grease particles suspended in the air and are therefore subject to clogging because of frequent use.
List of Parts and Accessories www.zephyronline.
3LIK0482