Use and Care Manual

22
PRKB24C01AG & PRKB24C01AS-OD Use, Care, and Installation Guide
KEGERATOR &
BEVERAGE COOLER
INDOOR & OUTDOOR
PRESRV™
Installation Instructions
1. With the shuto valve on the regulator turned
o (perpendicular to the tubing), completely
open the hand valve on the CO₂ tank (FIG. L).
2. Turn the pressure adjustment knob until the
desired pressure is shown on the low pressure
guage (FIG. M). We recommend setting the
regulator between 10-12 PSI to start and adjust
later as needed. Turn the knob clockwise to
increase pressure and counterclockwise to
decrease pressure.
NOTE: Other conditions such as altitude or beer
type may require additional adjustments.
3. Open the shuto valve on the regulator so it is
parallel with the tubing (FIG N).
4. The keg coupler is designed with a pressure
relief valve (PRV) as shown in FIG. O. Briefly
pull the ring on the PRV to allow CO₂ gas to
vent. This will permit CO₂ gas to flow through
the regulator and help obtain a more accurate
reading on the low pressure guage.
NOTE: We recommend following up on any
adjustment to the regulator with a brief pull of the
PRV ring to ensure an accurate output reading.
Check for leaks.
FIG. L
Pressure adjustment knob
FIG. M
Calibrating the Regulator
FIG. N
FIG. O