Use, Care, and Installation Guide www.zephyronline.com Milano Island ZML-M90AG/AS ZML-E42AG/AS Model number: Serial Number: FEB09.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... Hood Specifications ................................................... Mounting the Hood ..................................................... Ductless Recirculation .............................................. 5 6 7 8 9 - 10 11 CONTROLS.......................................................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
List of Materials www.zephyronline.
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6”- 8” Round 30 Ft. wall cap with damper x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6”- 8” Round, 30 Ft. roof cap x( ) = Ft. 8” Round, straight 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect. 90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect. 45 0 elbow x( ) = Ft. 6” round to 16 Ft.
Installation – Mounting Height & Clearance www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 28”. Maximum mount height should be no higher than 36”. Min. ducted 28” Min. recirc. 28” Max. 38” It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
front of hood side of hood 10 13/16” 10 3/8” (blower housing) min. ducted - 28” min. recirc. - 28” max. - 38” 26” 23 15/16” 35 7/16” or 41 15/16” top of hood (blower housing & ceiling bracket) 8 1/4” 8 3/4” 15” Installation – Hood Specifications www.zephyronline.com 4” 6”Ø elec.
Ceiling Joists Wood Blocking fron Fr on t side t 1 FIG. B 3 Top Support Frame 2 Bottom Support Frame Bottom Support Frame back 5 2. Key hole 6 1. Wider cut out FIG. C Hood/Canopy 4 front FIG. A Installation – Mounting the Hood Top Support Frame ! CAUTION: At least two installers are required due to the weight and size of the hood. 1. *Determine desired mounting location on ceiling and add wood blocking (min. 2” x 4”) onto ceiling joists. (FIG. A, #1) 2.
Installation – Mounting the Hood www.zephyronline.com cut-down canopy Top support frame 10 9 Top duct covers 13 Thick trim piece 12 (Bottom of the hood) Bottom duct covers 11 Thin trim piece Bottom support frame screw holes (4) for the canopy FIG. E FIG. D 7. Install electrical and duct work. Seal duct work with aluminum duct tape. 8. Power up hood and check for leaks around duct tape. 9. *Assemble top duct covers (with louver holes) together using (2) M3 x 6 screws. (FIG. E, #9).
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. The hood is most effective and efficient as an exhaust hood. Only when the exhaust option is not possible should you recourse to converting the hood into a recirculating hood. When converted to be a recirculating hood, a set of charcoal filters are required on top of its standard Metal Filter set. Order according to its Part number below.
Features & Controls – Touch Controls www.zephyronline.com Blower On/Off Display (speed level, delay off, filter clean/change) Lights On/Dim/Off Adjust 6 Speed Levels 15 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 3. 2. Speed Selection The 6 speed levels are selected by pressing selected. to decrease and to increase speed levels. The display indicates levels 3.
The filter change reminder function in the microprocessor needs to be switched on. When switched on, the microprocessor will elapse and count usage time and indicate by a flashing C when charcoal filter replacements are needed. Setting the Filter Change Reminder When off, hold for approximately 5 seconds. The display will change from (exhaust mode) to C (recirculating mode) this indicates that the elapse timer function is switched on and charcoal filters are used. Set Mode hold 5 sec.
Features & Controls – Metal Mesh Filter Clean Reminder www.zephyronline.com Metal Filter Clean Reminder (metal mesh filter) Whether your hood is installed as an exhaust or purifying unit, a set if metal mesh filters are fitted by the factory, These metal mesh filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain. Do not use any product containing chlorine bleach. Do not use “orange” cleaners.
Maintenance – Lights www.zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out.
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3. Make sure the wirings between the switch board and control board are connected properly. 4.
List of Parts and Accessories www.zephyronline.com DESCRIPTION PART# Replacement Parts Light Bulb GU10 50W (each) Metal Filter (each) Z0B-0020 50200011 Optional Accessories Recirculating Kit Replacement Charcoal Filter (each) Duct Cover Extension ZRC-0190 Z0F-C002 Z1C-02ML To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain service under warranty Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Two Year Limited Warranty f