WWW.ZEPHYRONLINE.COM Ombra ZOM-E30BS, ZOM-E30BBS, ZOM-E36BS, ZOM-E36BBS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology JAN21.
CORE MILANO WA L L 2 Milano Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information ............................................................................ 4-6 Types of Safety Warnings ................................................................... 4 General Safety ..................................................................................4-5 Operation ........................................................................................... 6 Electrical Requirements ........................................................
CORE Safety Information MILANO WA L L READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. This is the Safety Alert Symbol.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
CORE Safety Information MILANO WA L L READ AND SAVE THESE INSTRUCTIONS Operation Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
List of Materials ZEPHYRONLINE.
CORE Installation Instructions MILANO WA L L Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A n. i m . B n mi x. C ma D n. i m . E n mi x. F ma in..
CORE Installation Instructions MILANO WA L L Mounting Height, Clearance, & Ducting A minimum of 6” round duct is recommended to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Also use the ducting calculation sheet (on page 8) to compute total available duct run when using elbows, transitions and caps. ALWAYS, when possible, reduce the number or transitions and turns.
Installation Instructions ZEPHYRONLINE.COM Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Ź Use single wall rigid metal ductwork only. Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
CORE Installation Instructions MILANO WA L L Ů 8-3/4” 6-7/8” Z1C-01OMS Z1C-01OMBS min. ducted - 46-1/2” min. recirc. - 50-1/2” max. 80” 1-9/16” 12” Standard min. ducted - 30” min. recirc - 32” max.
Installation Instructions ZEPHYRONLINE.COM Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
CORE Installation Instructions MILANO WA L L Mounting the Hood C/L CAUTION Duct Cover Bracket At least two installers are required due to the weight and size of the hood. 3-1/2" B 1. Measure from range top to hood bottom and mark line A. (26” minimum from range top). 2. Plum and mark center line. 2" 12-1/4" A 3. Mark mounting height line B. (12-1/4” from line A). 4. Mark mounting spread from C/L on line B. From C/L to left mount mark (3-1/2”). From C/L to right mount mark (2”).
Installation Instructions ZEPHYRONLINE.COM Mounting the Hood 9. (If applicable) If using hood in recirculating mode you must secure the air diverter plate onto wall before installing duct work and duct covers. Turn to page 16 for more details. 10. Install duct work and seal all joints with certified duct tape. 11. Power up hood and check for leaks around duct tape. 12. Place telescopic duct covers onto hood and extend inner (top) duct cover upwards and secure to duct cover bracket using (2) M4 x 8 screws.
CORE Installation Instructions MILANO WA L L Ductless Recirculation Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.
Installation Instructions ZEPHYRONLINE.COM Charcoal Filter Replacements Hood Model Part Number ZOM-E30BS ZOM-E30BBS ZOM-E36BS ZOM-E36BBS Z0F-C091 Z0F-C091 Z0F-C091 Z0F-C091 Quantity to Order 2 2 2 2 DO NOT WASH CHARCOAL FILTERS. Charcoal filters may need to be changed more often depending on cooking habits. FIG.
CORE Features & Controls MILANO WA L L Touch Controls 5 Delay Off Timer Indicator 6 Speed Indicators 1 Power / Delay Off 4 Lights On/Off 8 Lights Indicator Q 2 3 4 clean filters 3 Fan Speed Increase 7 Clean Filter Indicator Fan Speed Decrease 1 ħ Ű Button will turn power on and off for entire hood (fan and lights. - Hood will remember the last speed and light level it was last turned off at. (Example: Press button to turn off hood when on fan speed 3 and high lights.
Features & Controls ZEPHYRONLINE.COM Touch Controls 5 Ű - When delay off function is activated, delay off indicator light will turn on indicating the delay off 5 minute timer has started. - After 5 minutes the fan, lights and delay off indicator will automatically turn off. 6 Speed Level Indicators - Fan is four speed levels. Q (Quiet), 2, 3, and 4.
CORE Maintenance MILANO WA L L Hood & Filter Cleaning Surface Maintenance Ź Do not use corrosive detergents, abrasive detergents or oven cleaners. Ź Do not use any product containing chlorine bleach or any product containing chloride. Ź Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
Maintenance ZEPHYRONLINE.COM Replacing Aluminum Mesh Filters Hood Model ZOM-E30BS/ ZOM-E30BBS ZOM-E36BS/ ZOM-E36BBS Part Number 50200059 50200059 Quantity to Order 2 2 To order parts, visit us online at http://store.zephyronline.com. LumiLight LED In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information. LED Removal (FIG. D): 1. Remove aluminum mesh filter. 2.
CORE ACT™ Conversion MILANO WA L L ů Ĭ Ļĭ Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT™ enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels; 390 or 290 CFM. The usage of ACT™ may not be necessary for your installation.
ACT™ Conversion ZEPHYRONLINE.COM Enabling ACT™ To enable ACT™: 1. Before hood installation, gain access to PC board by following the steps shown on FIG. E. 2. Change plastic jumper positioning as shown in FIG. F to set the desired maximum blower CFM. 3. Re-install PC board and continue with hood installation. 4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below the wiring diagram or in another clearly visible location.
CORE Wiring Diagram MILANO WA L L RED YELLOW MOTOR GREEN BODY YELLOW GREEN BODY LED LED Śśř ŚśĘŞƁŚśĘŞų śŞř Śśř şř 24 Milano Use, Care, and Installation Guide
Troubleshooting ZEPHYRONLINE.COM Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. The unit is vibrating. Possible Cause Solutions The power source is not turned ON. Make sure the circuit breaker and the unit’s power is ON. The power line and the cable locking connector is not connecting properly. The switch board or control board wirings are disconnected. The switch board or control board is defective. The wires on control board are loose.
CORE Troubleshooting MILANO WA L L Possible Problem The hood is not venting out properly. Mesh filter is vibrating. Possible Cause Solutions Using the wrong size of ducting. Change the ducting to the correct size. The hood might be hanging to high from the cook top. Adjust the distance between the cook top and the bottom of the hood within 26” and 34” range. Close all the windows and doors to eliminate the outside wind flow.
List of Parts & Accessories ZEPHYRONLINE.COM Description Replacement Parts LumiLight LED, 6W Aluminum mesh filter Optional Accessories Make-up Air Kit Duct Cover Extension, Stainless Duct Cover Extension, Black Stainless Recirculating Kit Replacement Charcoal Filter Baffle Filter Kit Part Number Z0B0047 50200059 MUA006A Z1C-01OMS Z1C-01OMBS ZRC-01OM Z0F-C091 Z0F-B002 To order parts, visit us online at http://store.zephyronline.com.
CORE Notes MILANO WA L L 28 Milano Use, Care, and Installation Guide
Limited Warranty ZEPHYRONLINE.
CORE Product Registration MILANO WA L L Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Ombra ZOM-E30BS, ZOM-E30BBS, ZOM-E36BS, ZOM-E36BBS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology JAN21.
CORE MILANO MUR 2 Milano Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité ....................................................................... 4-6 Types d’avertissements de sécurité ..................................................... 4 Sécurité générale...............................................................................4-5 Opération ........................................................................................... 6 Exigences électriques .......................................................
CORE Consignes de sécurité MILANO MUR LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps. AVERTISSEMENT AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES, RESPECTEZ LES SUIVANTS: a) N’utilisez cet appareil que de la manière prévue par le fabricant.
Consignes de sécurité ZEPHYRONLINE.
CORE Consignes de sécurité MILANO MUR LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération Ź Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. Ź Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Liste de matériel ZEPHYRONLINE.
CORE Instructions d’installation MILANO MUR Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit = 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit 3-1/ 4” x 10” rect.
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine A n. i m . B n mi x. C ma D n. i m . E n mi x. F ma in.. m ” x 24” ma 34 ” 36 Hauteur de la hotte min. avec conduit (A) min. avec recirc. d’air (B) maximum (C) Recouvrement de conduit standard 30 po 32 po 42-1/2 po Prolongement de rec. de conduit 46-1/2 po 50-1/2 po 80 po Hauteur de plafond 90 po (7 pi 6 po) 106-1/2 po (8 pi 10-1/2 po) min.avec conduit (D) min. avec recirc.
CORE Instructions d’installation MILANO MUR Hauteur de montage, dégagement et gaine Un conduit rond d’au moins 6 po est recommandé pour maintenir une efficacité maximale du débit d’air. Utilisez toujours uniquement des conduits métalliques de type rigide. Les conduits flexibles peuvent restreindre le débit d’air jusqu’à 50%.
Instructions d’installation ZEPHYRONLINE.COM Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. Ź Utilisez uniquement des conduits métalliques rigides à paroi simple.
CORE Instructions d’installation MILANO MUR ¯ Ů 8-3/4 po 6-7/8 po la norme min. conduit - 30 po min. recirc - 32 po max. 42-1/2 po 12 po 1-9/16 po Z1C-01OMS Z1C-01OMBS min. conduit - 46-1/2 po min. recirc. - 50-1/2 po max.
Instructions d’installation ZEPHYRONLINE.COM Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
CORE Instructions d’installation MILANO MUR Montage de la hotte L/C ATTENTION Support de couvercle de conduit Au moins deux installateurs sont nécessaires en raison du poids et de la taille de la hotte. 1. Mesurez du haut de la cuisinière au bas de la hotte et marquez la ligne A. (26 po minimum du haut de la cuisinière). 3-1/2 po 2 po B 12-1/4 po A 2. Prune et marquez la ligne centrale. 26 po min 3. Marquer la ligne de hauteur de montage B. (121/4 po de la ligne A).
Instructions d’installation ZEPHYRONLINE.COM Montage de la hotte 8. Installez électrique. 9. (Le cas échéant) Si vous utilisez la hotte en mode de recirculation, vous devez fixer la plaque de dérivation d’air sur le mur avant d’installer les conduits et les couvercles de conduits. Allez à la page 16 pour plus de détails. 10. Installer des conduits et sceller tous les joints avec du ruban adhésif certifié. 11. Mettez la hotte sous tension et vérifiez les fuites autour du ruban adhésif. 12.
CORE Instructions d’installation MILANO MUR Recirculation sans conduit La recirculation sans conduit est destinée aux applications où un conduit d’évacuation ne peut pas être installé. Une fois convertie, la hotte fonctionne comme une hotte à recirculation plutôt qu’une hotte aspirante. Les fumées et les gaz d’échappement de la cuisson sont aspirés et filtrés par un ensemble de filtres à charbon en option. L’air est ensuite purifié et remis en circulation dans la maison.
Instructions d’installation ZEPHYRONLINE.COM Ů £ Modèle de hotte ZOM-E30BS ZOM-E30BBS ZOM-E36BS ZOM-E36BBS Numéro de pièce ZRC-01OM ZRC-01OM ZRC-01OM ZRC-01OM Quantité à commander 2 2 2 2 NE PAS LAVER LES FILTRES À CHARBON. Les filtres à charbon peuvent devoir être changés plus souvent selon les habitudes de cuisson. FIG.
CORE Fonctionnalités et commandes MILANO MUR Commandes tactiles 5 Indicateur de la minuterie de l’arrêt à retardement 1 Mise en marche/Arrêt à retardement Q 6 Indicateurs de vitesse 4 Lumières Allumer/Éteindre Indicateur des lumières 8 2 3 4 clean filters 3 Augmentation de la vitesse du ventilateur 7 Indicateur de nettoyage des filtres Réduction de la vitesse du ventilateur 1 Mise en marche/Arrêt à retardement - La touche permet d’allumer et d’éteindre la hotte (le ventilateur et les lumières).
Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes tactiles 5 Ġ² £ - Lorsque vous activez la fonction d’arrêt à retardement, le témoin lumineux d’arrêt à retardement s’allume, indiquant que le compte à rebours de 5 minutes de la minuterie a commencé. - Après 5 minutes, le ventilateur, les lumières et l’indicateur de l’arrêt à retardement s’éteignent automatiquement. 6 Indicateurs de vitesse - Le ventilateur peut être ajusté à l’une des quatre vitesses.
CORE Entretien MILANO MUR Ů Entretien de surface Ź N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. Ź N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. Ź N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
Entretien ZEPHYRONLINE.COM Ů £ Modèle de capot Numéro d’article ZOM-E30BS/ ZOM-E30BBS 50200059 ZOM-E36BS/ ZOM-E36BBS 50200059 Quantité à commander 2 2 Pour commander des pièces, visitez-nous en ligne à http://store.zephyronline.com. LumiLight LED Dans le cas peu probable où votre LumiLight LED tombe en panne, veuillez contacter Zephyr pour commander des pièces de rechange.
CORE Conversion ACT™ MILANO MUR Technologie de contrôle du débit d’air (ACT™) Certains codes locaux limitent la quantité maximale de CFM qu’une hotte de cuisinière peut déplacer. ACT™ vous permet de contrôler le CFM maximum du ventilateur de certaines hottes de cuisinière Zephyr Ventilation sans avoir besoin de kits d’air d’appoint coûteux. ACT™ permet à l’installateur de régler facilement la vitesse maximale du ventilateur à l’un des deux niveaux CFM les plus couramment spécifiés; 390 ou 290 CFM.
Conversion ACT™ ZEPHYRONLINE.COM Activer ACT™ Pour activer ACT™: 1. Avant l’installation de la hotte, accédez au tableau de circuits imprimés en suivant les étapes illustrées à la FIG. H. 2. Changez le positionnement du cavalier en plastique comme illustré à la FIG. I pour régler le CFM maximum souhaité du ventilateur. 3. Réinstallez la carte de circuit imprimé et poursuivez l’installation de la hotte. 4.
CORE Schéma de câblage MILANO MUR 0 ROUGE MOTEUR CORPS NOIR CORPS LED LED Śśř ŚśĘŞƁŚśĘŞų śŞř Śśř şř 24 Milano Guide d’utilisation, d’entretien et d’installation
Dépannage ZEPHYRONLINE.COM Problème possible Après l'installation, l'appareil ne fonctionne pas. La lumière fonctionne, mais le ventilateur ne tourne pas. L'unité vibre. L'unité siffle. Le ventilateur fonctionne, mais les LED LumiLight ne le sont pas. Cause possible Solutions La source d'alimentation n'est pas allumée. Assurez-vous que le disjoncteur et l’appareil sont sous tension. La ligne d'alimentation et le connecteur de verrouillage du câble ne se connectent pas correctement.
CORE Dépannage MILANO MUR Problème possible La hotte ne s'échappe pas correctement. Cause possible Utilisation de la mauvaise taille de conduit. Changer le conduit à la bonne taille. La hotte est peut-être suspendue trop haut de la table de cuisson. Ajustez la distance entre la plaque de cuisson et le bas de la hotte dans les limites de 26 po et 34 po. Fermez toutes les fenêtres et portes pour éliminer le vent extérieur.
Liste des pièces et accessoires ZEPHYRONLINE.COM La description Pièces de rechange LumiLight LED, 6 W Filtre à mailles en aluminium Accessoires optionnels Kit air d'appoint Rallonge de couvercle de conduit, acier inoxydable Rallonge de couvercle de conduit, acier inoxydable noir Kit de recirculation Filtre à charbon de rechange Kit de filtre déflecteur Numéro d’article Z0B0047 50200059 MUA006A Z1C-01OMS Z1C-01OMBS ZRC-01OM Z0F-C091 Z0F-B002 Pour commander des pièces, visitez-nous en ligne à http://store.
CORE Remarques MILANO MUR 28 Milano Guide d’utilisation, d’entretien et d’installation
Garantie limitée ZEPHYRONLINE.
CORE Enregistrement du produit MILANO MUR Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.