Troubleshooting
The hood is not venting
out properly.
Using the wrong size of ducting. Change the ducting to the correct size.
The hood might be hanging to high
from the cook top.
Adjust the distance between the cook top
and the bottom of the hood within 26” and
34” range.
The wind from the opened windows
or opened doors in the surrounding
area are aecting the ventilation of
the hood.
Close all the windows and doors to eliminate
the outside wind flow.
Blockage in the duct opening or
ductwork.
Remove all the blocking from the duct work
or duct opening.
Mesh filter is vibrating. Filter is loose. Make sure the metal clips in the handle are
not stuck or replace the mesh filter.
Spring clip is broken on the filter. Uninstall and re-install filter. Push up on
filter latch. Replace filter if needed.
Possible Problem Possible Cause Solutions