WWW.ZEPHYRONLINE.COM Roma Groove ZRG-E30BS ZRG-M90BS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation AUG22.
CORE ROMA GROOVE WA L L 2 Roma Groove Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information............................................................................. 4-7 Types of Safety Warnings.................................................................... 4 General Safety.................................................................................... 4 Operation............................................................................................ 6 Electrical Requirements.........................................................
CORE Safety Information ROMA GROOVE WA L L READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
CORE Safety Information ROMA GROOVE WA L L READ AND SAVE THESE INSTRUCTIONS Operation ► Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. ► The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. FCC Notice CAUTION Any changes or modifications not expressly approved by Zephyr Ventilation for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of FCC Rules.
CORE List of Materials ROMA GROOVE WA L L Parts Supplied Quantity 1 1 1 2 2 1 1 1 Part Hood Duct cover wall bracket Duct cover assembly (top and bottom) Baffle filters LumiLight LED (pre-installed) Bluetooth® stereo speakers (pre-installed) 6" round backdraft damper (pre-installed) Hardware package (4) M4 x 8 (6) M6 x 1” (3) Wire Nuts Parts Not Supplied Ducting, conduit and all installation tools Cable locking connector (if required by local codes) Duct cover extension (Z1C-00RO) 8 Roma Groove Use,
Installation Instructions ZEPHYRONLINE.COM Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
CORE Installation Instructions ROMA GROOVE WA L L Mounting Height, Clearance, & Ducting A n. i m . B n mi x. C ma D n. i m . E n mi x. F ma in..
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A minimum of 6” round duct must be used to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Use calculation worksheet to compute total duct work (Page 10). ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 6” to 7”.
CORE Installation Instructions ROMA GROOVE WA L L Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. ► Use single wall rigid metal ductwork only. ► Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Installation Instructions ZEPHYRONLINE.COM Hood Specifications 10- 7/8” STANDARD min. ducted - 27” min. recirc. - 31-1/2” max. - 48-1/2” 11- 7/8” 14- 1/8 ” 8” 3-7/8” Z1C-00RO EXTENSION min. ducted - 42” min. recirc. - 46” max.
CORE Installation Instructions ROMA GROOVE WA L L Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation Instructions ZEPHYRONLINE.COM Mounting the Hood CAUTION At least two installers are required due to the weight and size of the hood. 1. Adjust the mounting brackets by loosening (2) preinstalled screws per bracket. Duct Cover Bracket B A 3. Measure the range top to the hood bottom and mark line A (24” minimum from the range top). 24” min. 2. Mount the component box bracket onto the hood with (2) M4 x 8 screws with the component box facing outwards. C/L 4.
CORE Installation Instructions ROMA GROOVE WA L L Ductless Recirculation Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.
Installation Instructions ZEPHYRONLINE.COM Recirculating Kit Installation (required if no ducting is used) 3. Remove the baffle filters from the hood. Place the charcoal filters to the back side of the baffle filters. Secure the charcoal filters in place with rubber clips or magnets, depending on the filter design. NOTE: Remove all the black foam from the filter opening before installing the charcoal filters (FIG. D). 4. Reinstall the baffle filters. 5.
CORE Features & Controls ROMA GROOVE WA L L ICON Touch Controls Power / Delay Off Adjust 5 Speed Levels Lights Low/High/Off Display (speed level, delay off, filter clean/change) 1 POWER / DELAY OFF BUTTON Power Button Function Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights.
Features & Controls ZEPHYRONLINE.COM ICON Touch Controls 3 LIGHTS BUTTON - Lights have two levels, Low and High. - From off, press one time for Low. Press again for High. Press again to power lights off. 4 DISPLAY INDICATORS Baffle Filter Clean Reminder (always enabled) - After 30 hours of fan usage, the button indicator will begin to slowly blink indicating it is time to clean the baffle filters. - To reset: With hood off: hold the button for three seconds.
CORE Features & Controls ROMA GROOVE WA L L Bluetooth® Controls 1 2 3 4 Bluetooth® Play & Pause Decrease Volume Increase Volume Stereo Speaker uses Bluetooth® version 4.1 1. BLUETOOTH® BUTTON ► Power On & Pair the Device Press the button to turn on the speakers, indicated by (4) beeps from a low to high tone. And press the button again to sound the pairing process between the speakers and the device, indicated by (4) neutral tone beeps.
Features & Controls ZEPHYRONLINE.COM 4. INCREASE VOLUME BUTTON ► Increase Volume Press the button to increase the volume on the paired device. ► Next Track Hold the button to skip forward to the next track. NOTE: The hood blower or lights do not need to be powered on for the speakers to activate. In addition, the play & pause, decrease volume, and increase volume buttons can still be accessed from the user’s device.
CORE Features & Controls ROMA GROOVE WA L L How to connect to the Zephyr Bluetooth® Stereo Speakers each subsequent time (after the initial connection has been made): 1. The speakers can only play audio files from one connected device at a time. If another device was to connect to the speakers, the currently connected device must disconnect (but not necessarily unpair) from the speakers first. Disconnecting refers to stopping the connection between the speakers and the device.
Features & Controls ZEPHYRONLINE.COM Optional RF Remote Control To enable RF remote control capabilities, the remote control accessory kit is required. The part number for the kit is RC-0002. FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example use only shielded interface cables when connecting to computer or peripheral device.
CORE Features & Controls ROMA GROOVE WA L L Optional RF Remote Control RF Remote Features The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. E. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote. Maximum remote control communication distance is 15 feet from the liner. FIG.
Maintenance ZEPHYRONLINE.COM Hood & Grease Filter Cleaning Surface Maintenance ► Do not use corrosive detergents, abrasive detergents or oven cleaners. ► Do not use any product containing chlorine bleach or any product containing chloride. ► Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
CORE Maintenance ROMA GROOVE WA L L Removing the Grease Filters (FIG. G): 1. Pull down on filter latch to release the filter tabs. 2. Pull down on front of filter to remove the grease filters. FIG. G LumiLight LED In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information. LED Removal (FIG. H): 1. Remove grease filters. 2.
ACT™ Conversion ZEPHYRONLINE.COM Airflow Control Technology (ACT™) Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT™ enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels; 390 or 290 CFM. The usage of ACT™ may not be necessary for your installation.
CORE ACT™ Conversion ROMA GROOVE WA L L Enabling ACT™ To enable ACT™: 1. Before hood installation, gain access to PC board by following the steps shown in FIG. I. 2. Change plastic jumper positioning as shown in FIG. J to set the desired maximum blower CFM. 3. Re-install PC board and continue with hood installation. 4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below the wiring diagram or in another clearly visible location.
Wiring Diagram ZEPHYRONLINE.COM ZRG Wiring Diagram Volts Hz 120 60 Max Amps 4 BODY MOTOR WHITE BLACK P/C Power Supply RED RED YELLOW BLUE BROWN GREY WHITE WHITE BLACK YELLOW YELLOW YELLOW YELLOW GREEN Speaker BLACK WHITE Bluetooth Controller GREEN BODY Controller LED LED REMARKS: CONDENSER 12.5 + 12.
CORE Troubleshooting ROMA GROOVE WA L L Possible Problem Possible Cause After installation, the unit The power source is not turned ON. doesn’t work. The power line and the cable locking connector is not connecting properly. Check the power connection with the unit is connected properly. The switch board or control board wirings are disconnected. Make sure the wirings at the switch board and control board are connected properly. The switch board or control board is defective.
Troubleshooting ZEPHYRONLINE.COM Possible Problem The hood speakers will not pair with the user’s device. Possible Cause The speaker’s Bluetooth® is not actively pairing with any devices. Solutions Press the Bluetooth® button to signal the pairing process. The speaker’s Bluetooth® has stopped pairing with devices, signaled by a sound indication. Hold the Bluetooth® button for a few seconds to turn off the device. Restart the pairing process by pressing the Bluetooth® button.
CORE List of Parts & Accessories ROMA GROOVE WA L L Description Replacement Parts Replacement Charcoal Filter LumiLight LED, 6W Baffle Filter Optional Accessories Recirculating Kit Duct Cover Extension Make-up Air Kit Remote Control Kit RF Remote Control (remote w/ battery only) Part Number Z0F-C005 Z0B0048 50210034 ZRC-00RG Z1C-00RO MUA006A RC-0002 14000005 To order parts, visit us online at http://store.zephyronline.com.
Limited Warranty ZEPHYRONLINE.COM Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS United States Customers please call: 1-888-880-8368 or contact us at: zephyronline.com/contact Canada Customers please call: 1-800-361-0799 or Email: service@distinctive-online.
CORE Product Registration ROMA GROOVE WA L L Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Roma Groove ZRG-E30BS ZRG-M90BS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation AUG22.
CORE ROMA GROOVE MUR 2 Roma Groove Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité........................................................................ 4-7 Types d’avertissements de sécurité...................................................... 4 Sécurité générale................................................................................. 4 Opération............................................................................................ 6 Exigences électriques.......................................................
CORE Consignes de sécurité ROMA GROOVE MUR LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps. AVERTISSEMENT AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES, RESPECTEZ LES SUIVANTS: a) N’utilisez cet appareil que de la manière prévue par le fabricant.
Consignes de sécurité ZEPHYRONLINE.
CORE Consignes de sécurité ROMA GROOVE MUR LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération ► Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. ► Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Consignes de sécurité ZEPHYRONLINE.COM LISEZ ET CONSERVEZ CES INSTRUCTIONS La marque verbale et les logos Bluetooth® sont des marques déposées appartenant à Bluetooth SIG, Inc. Avis de la FCC AVERTISSEMENT Tout changement ou modification non expressément approuvé par Zephyr Ventilation pour la conformité pourrait annuler l’autorité de l’utilisateur à faire fonctionner l’équipement. Cet appareil est conforme à la partie 15 des règles de la FCC.
CORE Liste de matériel ROMA GROOVE MUR Pièces fournies Quantité 1 1 1 2 2 1 1 1 Partie Hotte Support mural pour couvercle de conduit Assemblage du couvercle du conduit (haut et bas) Filtres à chicane LumiLight LED (préinstallée) Haut-parleurs stéréo Bluetooth® (préinstallés) Clapet anti-retour rond de 6 po (pré-installé) Pack matériel (6) M6 x 1 po (4) M4 x 8 (3) Fil Écrous Pièces non fournies Conduits, conduits et tous les outils d’installation Raccord de câble (si requis par les codes locaux) Rallo
Instructions d’installation ZEPHYRONLINE.COM Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit = Longueur x Nombre utilisé Pièces de conduit Total 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect.
CORE Instructions d’installation ROMA GROOVE MUR Feuille de calcul pour le conduit d’aération A n. mi . B n mi x. C ma D n. i m . E n mi x. F ma in..
Instructions d’installation ZEPHYRONLINE.COM Feuille de calcul pour le conduit d’aération Un conduit rond d’au moins 6 po doit être utilisé pour maintenir une efficacité maximale du débit d’air. Utilisez toujours uniquement des conduits métalliques de type rigide. Les conduits flexibles pourraient restreindre le débit d’air jusqu’à 50%. Utilisez la feuille de calcul pour calculer le travail total des conduits (page 10). TOUJOURS, dans la mesure du possible, réduire le nombre de transitions et de virages.
CORE Instructions d’installation ROMA GROOVE MUR Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. ► Utilisez uniquement des conduits métalliques rigides à paroi simple.
Instructions d’installation ZEPHYRONLINE.COM Spécifications de la hotte 10- 7/8 po 14- 1/8 po 11- 7/8 po STANDARD min. ducted - 27 po min. recirc. - 31-1/2 po max. - 48-1/2 po 8 po 3-7/8 po Z1C-00RO EXTENSION min. ducted - 42 po min. recirc. - 46 po max.
CORE Instructions d’installation ROMA GROOVE MUR Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
Instructions d’installation ZEPHYRONLINE.COM Montage de la hotte AVERTISSEMENT 1. Ajustez les supports de montage en desserrant (2) vis préinstallées par support.Montez le support de la boîte de composants sur la hotte avec (2) vis M4 x 8 avec la boîte de composants tournée vers l’extérieur. B A 2. Mesurez le haut de la cuisinière jusqu’au bas de la hotte et marquez la ligne A (24 po minimum à partir du haut de la cuisinière). Marquez la ligne centrale verticalement. 24 po min.
CORE Instructions d’installation ROMA GROOVE MUR Recirculation sans conduit La recirculation sans conduit est destinée aux applications où un conduit d’évacuation ne peut pas être installé. Une fois convertie, la hotte fonctionne comme une hotte à recirculation plutôt que comme une hotte aspirante. Les fumées et les gaz d’échappement de la cuisson sont aspirés et filtrés par un ensemble de filtres à charbon en option. L’air est ensuite purifié et recyclé dans la maison.
Instructions d’installation ZEPHYRONLINE.COM Installation du kit de recirculation (requis si aucun conduit n’est utilisé 3. Retirez les filtres déflecteurs de la hotte. Placez les filtres à charbon à l’arrière des filtres à chicane. Fixez les filtres à charbon en place avec des clips en caoutchouc ou des aimants, selon la conception du filtre. REMARQUE: Retirez toute la mousse noire de l’ouverture du filtre avant d’installer les filtres à charbon (FIG. D). 4. Réinstallez les filtres déflecteurs. 5.
CORE Fonctionnalités et commandes ROMA GROOVE MUR Commandes tactiles ICÔNE Mise en marche/Arrêt à retardement Choix de 5 vitesses Lumières: faible / élevée / éteinte Afficheur (vitesse, arrêt à retardement, nettoyage/changement des filtres) 1 MISE EN MARCHE/ARRÊT À RETARDEMENT Fonction de la touche de mise en marche - La touche permet d’allumer et d’éteindre toutes les fonctions de la hotte (ventilateurs et lumières).
Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes tactiles ICÔNE 3 TOUCHE DE CONTRÔLE DES LUMIÈRES - Il existe deux intensités: basse et haute. - Lorsque les lumières sont éteintes, appuyez une fois pour les allumer à faible intensité. Appuyez à nouveau pour les mettre en hauteur. Appuyez à nouveau pour les désactiver.
CORE Fonctionnalités et commandes ROMA GROOVE MUR Bluetooth® Controls 1 2 3 4 Bluetooth® Jouer pause Diminuer le volume Augmenter le volume Le haut-parleur stéréo utilise Bluetooth® version 4.1 1. BOUTON BLUETOOTH® ► Allumer et appairer l’appareil Appuyez sur le bouton pour allumer les haut-parleurs, indiqués par (4) bips d’un ton bas à haut. Et appuyez à nouveau sur le bouton pour faire retentir le processus d’appairage entre les haut-parleurs et l’appareil, indiqué par (4) bips neutres.
Fonctionnalités et commandes ZEPHYRONLINE.COM 4. BOUTON D’AUGMENTATION DU VOLUME ► Augmenter le volume Appuyez sur le bouton ► Piste suivante Maintenez la touche pour augmenter le volume sur l’appareil couplé. enfoncée pour passer à la piste suivante. REMARQUE : Le ventilateur de la hotte ou les lumières n’ont pas besoin d’être allumés pour que les haut-parleurs s’activent.
CORE Fonctionnalités et commandes ROMA GROOVE MUR Comment se connecter aux haut-parleurs stéréo Zephyr Bluetooth® à chaque fois (après que la connexion initiale a été établie): 1. Les haut-parleurs ne peuvent lire les fichiers audio que d’un seul appareil connecté à la fois. Si un autre appareil devait se connecter aux haut-parleurs, l’appareil actuellement connecté doit d’abord se déconnecter (mais pas nécessairement dissocier) des haut-parleurs.
Fonctionnalités et commandes ZEPHYRONLINE.COM Télécommande RF en option Pour activer les capacités de télécommande RF, le kit d’accessoires de télécommande est requis. Le numéro de pièce du kit est RC-0002. Attention FCC Pour assurer la conformité continue, tout changement ou modification non expressément approuvé par la partie responsable de la conformité peut annuler le droit de l’utilisateur à utiliser cet équipement.
CORE Fonctionnalités et commandes ROMA GROOVE MUR Télécommande RF en option Caractéristiques de la télécommande RF La télécommande RF est équipée d’un aimant à l’arrière pour un rangement facile. La télécommande peut être placée sur n’importe quelle surface magnétique telle qu’un réfrigérateur ou le support de télécommande Zephyr, FIG. E. Le support à distance peut être inséré dans une prise électrique standard pour un rangement facile.
Entretien ZEPHYRONLINE.COM Nettoyage de la hotte et du filtre à graisse Entretien de surface ► N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. ► N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. ► N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
CORE Entretien ROMA GROOVE MUR Retrait des filtres à graisse (FIG. G): 1. Tirez sur le loquet du filtre pour libérer les languettes du filtre. 2. Tirez sur le devant du filtre pour retirer les filtres à graisse. FIG. G LumiLight LED Dans le cas peu probable où votre LED LumiLight tomberait en panne, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la page de la liste des pièces et accessoires pour les numéros de pièces et les coordonnées. Retrait de la LED (FIG. H): 1.
Conversion ACT™ ZEPHYRONLINE.COM Technologie de contrôle du flux d’air (ACT™) Certains codes locaux limitent la quantité maximale de CFM qu’une hotte de cuisine peut déplacer. ACT™ vous permet de contrôler le CFM maximum du ventilateur de certaines hottes de cuisinière Zephyr Ventilation sans avoir besoin de trousses d’air d’appoint coûteuses. ACT™ permet à l’installateur de régler facilement la vitesse maximale du ventilateur sur l’un des deux niveaux CFM les plus couramment spécifiés ; 390 ou 290 PCM.
CORE Conversion ACT™ ROMA GROOVE MUR Activer ACT™ Pour activer ACT™ : 1. Avant l’installation de la hotte, accédez au tableau de circuits imprimés en suivant les étapes indiquées sur la FIG. H. 2. Modifiez la position du cavalier en plastique comme indiqué sur la FIG. I pour régler le CFM maximum désiré du ventilateur. 3. Réinstallez la carte de circuit imprimé et continuez l’installation de la hotte. 4.
Schéma de câblage ZEPHYRONLINE.
CORE Dépannage ROMA GROOVE MUR Problème possible Après l’installation, l’appareil ne fonctionne pas. La lumière fonctionne, mais le ventilateur ne tourne pas. L’appareil vibre. Le ventilateur fonctionne, mais les lumières ne fonctionnent pas. L’appareil s’allume tout seul. 30 Cause possible Solutions La source d’alimentation n’est pas allumée. Assurez-vous que le disjoncteur et l’alimentation de l’unité sont sur ON.
Dépannage ZEPHYRONLINE.COM Problème possible La hotte ne s’évacue pas correctement. Les haut-parleurs de la hotte ne seront pas couplés avec l’appareil de l’utilisateur. L’appareil de l’utilisateur ne sera pas jumelé avec les haut-parleurs du capot. Cause possible Solutions Utiliser la mauvaise taille de conduit. Changez le conduit à au moins 6 po rond ou plus. Utiliser le mauvais type de conduit. Les conduits flexibles peuvent réduire le débit d’air jusqu’à 50 %.
CORE Dépannage ROMA GROOVE MUR Problème possible L’appareil de l’utilisateur est jumelé avec les hautparleurs du capot, mais ne se connecte pas aux haut-parleurs. Les haut-parleurs du capot et l’appareil de l’utilisateur sont couplés et connectés, mais il n’y a pas de son. Le volume maximal diffusé par les hautparleurs est trop faible.
Liste des pièces et accessoires ZEPHYRONLINE.COM La description Pièces de rechange Filtre à charbon de rechange LumiLight LED, 6W Filtre à chicane Accessoires optionnels Kit de recirculation Rallonge de couvercle de conduit Kit d’air d’appoint Trousse de télécommande Télécommande RF (télécommande avec pile uniquement) Numéro d’article Z0F-C005 Z0B0048 50210034 ZRC-00RG Z1C-00RO MUA006A RC-0002 14000005 Pour commander des pièces, visitez-nous en ligne à http://store. zephyronline.com.
CORE Remarques ROMA GROOVE MUR 34 Roma Groove Guide d’utilisation, d’entretien et d’installation
Garantie limitée ZEPHYRONLINE.COM Garantie limitée POUR OBTENIR UN SERVICE SOUS GARANTIE OU POUR TOUTE QUESTIONS LIÉES AU SERVICE Les clients des États-Unis doivent appeler le: 1-888-880-8368 ou nous contacter à: zephyronline.com/contact Clients du Canada, veuillez appeler: 1-800-361-0799 ou par courriel: service@distinctive-online.
CORE Enregistrement du produit ROMA GROOVE MUR Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.