3. Remove the bae filters from the hood. Place the
charcoal filters to the back side of the bae filters.
Secure the charcoal filters in place with rubber
clips or magnets, depending on the filter design.
NOTE: Remove all the black foam from the filter
opening before installing the charcoal filters
(FIG. D).
4. Reinstall the bae filters.
5. Charcoal filters must be replaced after every 120
hours of use (or approximately every 3 to 4 months,
based on an average of 1 - 2 hours of daily cooking
time).
NOTE: DO NOT WASH CHARCOAL FILTERS. Charcoal
filters may need to be changed more often
depending on cooking habits.