www.zephyronline.com Venezia Use, Care, and Installation Guide ZVE-E30S ZVE-E36S ZVE-E42S Model number: Serial number: MAY07.0101 © Zephyr Corporation.
www.zephyronline.
2 3 Table of Contents SAFETY NOTICE .............................................. LIST OF MATERIALS ....................................... INSTALLATION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting .................................................................. Specifications ....................................................... Mounting the Hood and Duct Cover................ Ductless Recirculating ............................
www.zephyronline.com Important safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO RE DUCE TH E R IS K O F FIR E O R E LE C TR IC SHOC K, DO NOT US E TH IS FAN W ITH ANY S O LID-S TATE SP E E D C O NTRO L DEV IC E. WARNING TO RE DUCE TH E R IS K O F FIR E, E LE C TR IC SH O C K, O R INJU RY TO P E R SON S, O B S E RVE TH E FO LLO W ING: a. Use this unit only in the manner intended by the manufacturer, If you have questions, contact the manufacturer. b.
1 - Duct cover mounting bracket 1 - Packet of mounting screws w/anchors 1 - Butterfly damper NO DUCTING IS INCLUDED * Note: Zephyr recommends using 50LB EZ anchors if mounting hood onto drywall. These are not provided. but are readily available of most hardware stores.
www.zephyronline.com Equivalent number length x used = Installation - Ductwork Calculation Sheet Duct pieces Equivalent number length x used = Duct pieces Total Total 3 1/4” x 10” Rect., straight 1 Ft. x( ) = Ft. 6” Round 30 Ft. wall cap with damper x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6” Round, roof cap 30 Ft. x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6” round to 3 1/4” x 10” rect. transition 1 Ft. x( ) = Ft. 3 1/4” x 10” Rect. 90 0 elbow 15 Ft.
Maximum mount height should be no higher than 36". min. ducted - 32 1/2” min recirc. - 36” max. 51” 9-27/32" min. 28" - max. 36" * min. 97" ** max. 123" It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency. If available, also refer range manufacturer'sheight clearance requirements and recommended hood mounting height above range.
Installation - Ducting www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
14 1.87" 0.5" 6.5" -3/ 16 ” 2.78" 6" 19-11/16” 10.37" 21-21/32” 13.87" 1-19/32” min. ducted - 32 1/2” min. recirc. - 36” max. - 51” 9-27/32” 30 ”, 3 6”, 42 ” ” 24 3/4" Elec. K.O. ELECTRICAL - WARNING All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
I nstallation - M ounting the Hood & Duct Cover www.zephyronline.com 1. Measure from range top to hood bottom (28” min) Level and mark line A. C/L 2. Plum and mark center line. Duct Cover Bracket 3. Mark mounting height line B. (10-3/8” from line A) 4. Mark mounting spread from C/L (9-7/16”) 9-7/16" 5. Fasten E-Z anchors to wall (see below) as marked. B 6. Fasten screws provided onto EZ anchors, do not fasten screws all the way. 10-3/8" A 7. Hang hood onto screws and hand tighten (fig A).
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. The hood is most effective and efficient as an Exhaust unit. Only when the exhaust option is not possible should you recourse to converting the hood into a "purifying"unit. When converted to be a "purifying" unit, a set of charcoal filters are required on top of its standard Metal Filter set. Order according to its Part number below.
Features & Controls - Touch Controls & Features www.zephyronline.com 1. Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower starts up on speed level 3. 2. Speed Selection The 6 speed levels are selected by presing level selected. to decrease and to increase speed level. The display indicates 3. Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function is activated.
Setting the Filter Change Reminder: When Off, hold for approx. 5 seconds. The display will change from (exhaust mode) to , (purifying mode/ carbon filters used) this indicates that the elapse timer function is switched on and Charcoal Filters are used. Filter Replace Indicator: Set Mode hold 5 secs. Change Filters When the display starts flashing, the Charcoal Filters require replacement.
Features & Controls - Metal Filters Clean Indicator www.zephyronline.com Filter Clean Reminder (Standard Metal Filters fitted): Whether your hood is installed as an Exhaust or Purifying unit, a set of metal filters are fitted by the factory. These Metal Filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain. Do not use any product containing chlorine bleach. Do not use “orange” cleaners.
Maintenance - Lights www.zephyronline.com Replacing Light Bulbs CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. If bulbs are difficult to turn due to prolonged use, firmly attach a glass suction cup approx. the diameter of the bulb or use a rubber/ latex glove and turn counter clockwise.
Cause What to do After installation, the unit doesn’t work? 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3. Make sure the wirings between the switch board and control board are connected properly. 4.
Part# Light Bulb (JDR-E27) Z0B-0011 Metallic Filters (2 pk) Z0F-M042 Metallic Filters (3 pk) Z0F-M043 Telescopic Back Splash 30” Z0S-0013 Telescopic Back Splash 36” Z0S-0016 Telescopic Back Splash 42” Z0S-0012 Wire Spice Rack 30” Z0R-0013 Wire Spice Rack 36” Z0R-0016 Wire Spice Rack 42” Z0R-0012 List of Parts and Accessories Description To order parts, visit us online at : www.zephyronline.com and go to the parts store.
Warranty www.zephyronline.com TO OBTAIN SERVICE UNDER WARRANTY or any Service Related Questions, please call: 1-888-880-8368 Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty. TO OBTAIN SERVICE UNDER WARRANTY: You must present proof of original purchase date. Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.