- Paradyne Network Device Product Manual

Zhone Technologies, Inc. IMACS Product Book, Version 4
March 2001 Page 103
BERT Direction
LOOP BACKS T1/CSU T1/DSX E1/CEPT/HDSL
Toward Network Yes Yes Yes
Statistics Gathered By BERT
LOOP BACKS T1/CSU T1/DSX E1/CEPT/HDSL
Bit Errors (BE) Yes Yes Yes
Errored Seconds (ES) Yes Yes Yes
Severely Errored Seconds (SES) Yes Yes Yes
Consecutive Severely Errored Seconds (CSES) Yes Yes Yes
Out of Synchronization Seconds (OSS) Yes Yes Yes
Bit Error Rate (BER) Yes Yes Yes
Elapsed Seconds (ELAP) Yes Yes Yes
HDSL Errored Seconds N/A N/A Yes*
HDSL Severely Errored Seconds N/A N/A Yes*
HDSL Unavailable Seconds N/A N/A Yes*
* applicable only for the E1-HDSL plug-in module. Also the same statistics are available for the
remote end.
Voice Diagnostics
The software-initiated diagnostics supported on voice cards include the setting of both analog and digital loop backs
toward the network and the generation of Quiet Tone and a Digital MilliWatt signal on a port-by-port basis. The
operator can also monitor and set the state of the analog leads of any FXS, FXO or E&M port. They can set and
monitor the state of the ABCD signaling bits of the digitized voice signal. In cross-connect systems, test
functionality also includes the ability to generate test tones (300Hz, 1 kHz and 3 kHz) and transmit those toward the
user side or the network side of the system. Refer to Table 26 for detailed information on the diagnostic capabilities
of the voice cards.
Table 26—Diagnostic Capabilities of Voice Ports
2-wire
E&M
4-wire
E&M
4-wire
Extended
E&M
2-wire
FXS
2-wire
FXO
LOOP BACKS
On-Card Loop backs
Analog Toward Network Yes Yes Yes Yes Yes
Digital Toward Network Yes Yes Yes Yes Yes
SIGNALING MANIPULATION
Set Status of Analog Interface Leads Yes Yes Yes Yes Yes
Set Transmit ABCD Signaling Bits Yes Yes Yes Yes Yes
Set Receive ABCD Signaling Bits Yes* Yes* Yes* Yes* Yes*
Monitor Status of Analog Interface Leads Yes Yes Yes Yes Yes
Monitor Status of Transmit ABCD Signaling Bits Yes Yes Yes Yes Yes
Monitor Status of Receive ABCD Signaling Bits Yes Yes Yes Yes Yes
TONE GENERATION
Tones Supported
300 Hz Yes* Yes* Yes* Yes* Yes*
1 kHz Yes* Yes* Yes* Yes* Yes*
3 kHz Yes* Yes* Yes* Yes* Yes*